TECHNICAL DATA:
DIMENSIONS W x H x D:
WEIGHT:
NOMINAL OUTPUT:
CLASS pursuant to EN 13 240:
FLUE GAS OUTLET – top:
REQUIRED NEGATIVE PRESSURE IN THE CHIMNEY:
MEAN FLUE GAS TEMPERATURE:
FUEL:
FLUE GAS FLOW RATE:
INSTALLATION INSTRUCTIONS
The stoves are delivered in carton boxes, fixed on transport pallets. Preferably, the stoves should be
unpacked at the installation site. The stoves are designed for top flue connection.
Ambient conditions
If the stove is to be installed in a room with combustible or heat sensitive flooring, a solid
non-combustible floor protector is required under the stove. The floor protector should be
dimensioned to extend at least 20 cm to the back and lateral sides and 40 cm to the front of the stove.
Minimum clearance between the stove (sides and rear) and materials sensitive to heat is 45 cm.
Minimum clearance between the stove and heat sensitive materials within the area directly exposed
to heat in front of the stove shall be 80 cm.
The stove should be positioned on a level surface, in a room with sufficient fresh air supply to support
the combustion. If an aspirator (range or fireplace hood) or any other air consuming device is installed
in the same room, make sure to provide for regular inflow of fresh air through a separate opening
protected with a clog-proof grid.
Chimney connection
Common (standard) stovepipes and elbows of nominal diameter Ø120 mm (inner stovepipe diameter
is Ø118 mm) are recommended for the connection to the chimney.
Make sure that the stovepipe and elbow are tightly fastened together and that the connections of the
stovepipe with the flue outlet and with the chimney outlet are firm and tight.
D
8 N
ora
38x84,7x43,5 cm
63,5 kg
6 kW
1a
Ø118/120 mm
12 Pa
234 °C
wood
6,2 g/s
17
D
10 N
ora
38x98,7x43,5 cm
64,5 kg
7,2 kW
1a
Ø118/120 mm
12 Pa
243 °C
wood
6,7 g/s