10
OCV Series
Installation Guide
1. Inspect cable clamp for signs of
2. Insert cable through one
dirt, damage or wear.
side of the clamp.
4. Adjust cable to the
5. Release cable by depressing
desired length.
the clamp sockets as shown.
HANGING / SAFETY POINT
3. Loop cable around suspension
point and then into the other
side of the clamp.
Repeat 1-3 for secondary
safety attachment.
6. Attach the hanging cable to
the centre hole of the speaker bracket.
The safety cable can be attached to
either of the secondary holes.
EUROBLOCK
TAP SELECTOR
Installation Guide
1. Remove the euroblock connector from the socket.
2. Feed the cable through the rubber input seal, then connect the euroblock connector to the cable,
observing the correct polarity.
3. For connec tion to an amplifi er, use pins 1 and 2:
Pin 1 is positive
Pin 2 is negative
For connection to additional speakers in a distributed line, pins 3 and 4 are in parallel where:
Pin 3 is negative
Pin 4 is positive
4. Connect the euroblock connector, then replace the rubber input seal to ensure the speaker is sealed.
THE SPEAKER IS SUPPLIED IN LOW IMPEDANCE MODE.
NEVER CONNECT THE SPEAKER TO A 70/100 VOLT AMPLIFIER
WHILE IT IS SET FOR LOW IMPEDANCE.
5. The OCV 6 and OCV 8 are fi tted with 60 W transformers. When used in distributed-line systems,
the transformer can be tapped at 60 W, 30 W, and 15 W, with an additional 7.5 W tapping for
70.7 V line systems.
Quick Start Guide