STARTING THE ENGINE
See Figures 4 - 6.
NOTICE:
On a level surface with the engine off, check the lubricant
level before each use of the generator.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
To start generator the first time:
Add engine lubricant per the Operator's Manual
instructions.
Place the Easy Start dial to the COLD START (CHOKE)
position.
Fill the fuel tank per the Operator's Manual instructions.
Place the auto idle switch in the OFF position.
Pull the recoil starter until the engine starts.
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place. Initial starting of the
unit may require additional pulls to prime the fuel pump.
Allow the engine to run for 15-30 seconds, then move
the Easy Start dial to the RUN/RE-START position.
For quieter more efficient operation, place the auto idle
switch in the ON position.
To start subsequent times:
Unplug all loads from the generator.
Normal maintenance, replacement or repair of emission con-
trol devices and systems may be performed by any qualified
repair establishment or individual with original or equivalent
parts. Warranty and recall repairs must be performed by an
authorized service center; please contact customer service
for assistance.
WARNING:
Before inspecting, cleaning or servicing the machine, shut
off engine, wait for all moving parts to stop, and disconnect
spark plug wire and move it away from spark plug. Allow
30 minutes of cool down time before performing any
maintenance. Failure to follow these instructions can result
in serious personal injury or property damage.
OPERATION
Place the auto idle switch in the OFF position.
Turn the Easy Start dial to the COLD START position.
NOTE: When the Easy Start dial is in the COLD START
(top) position, the fuel will flow from the fuel tank to the
engine. If engine is warm, turn the Easy Start dial to the
RUN/RE-START (middle) position.
Pull the recoil starter until the engine runs.
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place. Initial starting of the
unit may require additional pulls to prime the fuel pump.
Allow the engine to run for 15-30 seconds, then move
the Easy Start dial to the RUN/RE-START position.
STOPPING THE ENGINE
See Figure 5.
Remove any load from the generator.
Place the Easy Start dial in the OFF/STORAGE position.
To stop the engine in an emergency situation:
Place the Easy Start dial in the OFF/STORAGE position.
While operating and storing, keep at least 3 feet of clear-
ance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of "cool down" time
before storage. Heat created by muffler and exhaust
gases could be hot enough to cause serious burns and/
or ignite combustible objects.
MAINTENANCE
When servicing, use only recommended or equivalent
replacement parts. Use of any other parts could create
a hazard or cause product damage.
NOTICE:
Periodically inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts,
caps, etc. Tighten securely all fasteners and caps and
do not operate this product until all missing or damaged
parts are replaced. Please contact customer service or
a qualifed service center for assistance.
14 — English
WARNING:
WARNING: