INSTALLATION
INSTRUCTIONS
WARNING
• Do not install the range hood unless the
electrical service provided meets the range
hood specifications.
• Observe all governing codes and ordinances
during installation. Contact your local building
department for further information.
• A qualified technician must complete the
installation of this built-in appliance. More than
one person is required to raise the hood into
place. The owner is responsible to make sure
the hood is properly installed.
1
Start by removing the baffle filters from the
bottom of the hood. Put them in a safe location
so that they will not be damaged.
2
if the hood will be installed so that air will
exhaust out of the back, the blowers must be
rotated into the correct position before hanging
the hood.
iNSTALLATiON iNSTRuCTiONS
Rotating the Blower
This range hood is equipped standard with a 8"
round vertical duct option. To convert from 8" round
vertical to 8" round horizontal ducting or 3-1/4" x 10"
rectangular horizontal ducting please following the
instructions below.
Vertical to Horizontal Ducting
Conversion
1
Disconnect the blower plug.
2
Remove the 4 screws on the interior of the hood
body which attach the single blower plate to the
top of the hood body. Remove the single blower
and blower plate.
3
At the back, knock out plate B for rectangular
ducting, or plate C for 8-inch round ducting.
B
15
C