GENERAL
The panel MACH2 230 is a control unit 230 Vac for 1 door or 2 doors swing gates,
with and without limit switch. The peculiarity of the MACH2 230 is the regulation
of separated pair, using the T1 and T2 trimmers (T1 regulates the pair during
the opening time in normal speed and T2 regulates the pair in the slowing).
Interacting on these control panels you can optimize the operation of the automa-
tism within the parameters of the existing regulations. The self-learnig program-
ming of the operating time and the transmitters simplifies the procedure of installa-
tion. The operating time of the gates are stored separately in order to have
two different operating times.
OPTIONS SELECTION USING THE DIP-SWICHT
OPTION
1
AUTOMATIC CLOSING
ON
Inserted automatic closing
OFF
Not inserted automatic closing
OPTION
2
RESIDENTIAL MODE / STEP BY STEP
ON
The automation always stops the operation to the limit switch: in
the opening movement it does not accept pulses; in the closing move-
ment it causes the inversion of the direction.
OFF
For each pulse the automation stops. With the dip 2 ON during the
closing movement a pulse causes the inversion of direction.
OPTION
3
ATTIVAZIONE PROGRAMMAZZIONE RADIO DAL TX
ON
The radio memory can not be opened by the transmitter
OFF
The radio memory can be opened by the transmitter
OPTION
4
WATER HAMMER FOR ELECTROLOCK
ON
Water hammer on
OFF
Water hammer off
OPTION
5
SETUP OF THE SAFETY CONTACT IN OPENING
ON
Opening safety operation: the control panel stops the movement and
inverts it for 2 sec
OFF
Opening safety operation: the control panel stops the movement
OPTION
6
FLASHING LIGHT FUNCTION
ON
Intermittent light
OFF
Fixed light
OPTION
7
SLOWING
ON
Inserted slowing
OFF
Not inserted slowing
OPTION
8
PULSE FOR PRESSURE IN CLOSING
ON
Every 180 min the control panel gives a closing pulse to the
motors for 2 sec, avoiding the deviation of the gates.
OFF
Function off
TRANSMITTER PROGRAMMING
The control panel can manage fixed and rolling code transmitters. The two systems can not be manged simultaneously but the
first programmed transmitter encodes the radio software.
The standard MACH2 230 can manage 254 transmitters.
Press the button P1 for 2 sec, the led L2 flashes, then press the button of the transmitter: the led L2 will flash twice to indicate that the tran-
smitter has been stored. After 6 sec the control panel will automatically exit from the programming function.
PEDESTRIAN PASSAGE PROGRAMMING (by transmitter)
Press the button P1 for 2 sec, release it and press it again for 1 sec, the led L2 starts to flash and for each pressure of the button of a
transmitter there is a quick double flash of the led L2. After 6 sec the control panel will automatically exit from the programming function.
The pedestrian passage is managed only by the complete movement of the first gate.
STORED CODES DELETING
Press the button P1 for 6 sec: when you release it, there is a quick flash of the led L3; after 6 sec the led L2 will be off.
OPENING TIME PROGRAMMING
The programming starts when the automation system is closed: the first operation is the opening; if not, invert the direction of
movement using the exchange of the motor phases on the terminal block.
It can be done pressing the buttons on the panel GATE1 (PG1) and GATE2 (PG2), or by pre-programmed transmitter: the first channel of the
TX is for the first gate, the second channel of the TX is for the second gate.
If it is made by transmitter, only the first channel must be programmed: the second channel will be recognized automatically.
To enter in the programming press P2 for 2 seconds and the LED L3 lights up, so at this point:
2 DOORS PROGRAMMING WITH SLOWING (OPTION 7 ON)
Inizio con funzionamento in apertura
Press PG1: the
Wait for your desired
first gate starts
opening time interval
the opening
between the first and the
operation.
second gate.
Segue con funzionamento in chiusura
Press PG2 the
Wait for your desired
second gate
closing time interval
starts the closing
between the first and the
operation.
second gate.
1 DOOR PROGRAMMING WITH SLOWING (OPTION 7 ON)
Press PG1:
Press PG1 where you
the gate starts
want to start the slo-
the opening
wing operation in the
operation.
opening operation.
PROGRAMMING WITHOUT SLOWING (OPTION 7 OFF)
Set the option 7 to OFF for the exclusion of the slowing. Follow the above-mentioned instructions (1 door or 2 doors programming with slo-
wing) without sending the pulses and the slowing in the opening and closing operation. Then the pulses transmitted for the start of the opera-
tions will stop with the stop pulses.
Press PG2: the
Press PG1 where you want
gate starts the
to start the slowing operation
opening opera-
of the first gate and PG2 for
tion.
the slowing of the second
gate.
Press PG1 the
Press PG2 where you want to
first gate starts
start the slowing operation of
the closing ope-
the second gate and PG1 for
ration.
the slowing operation of the
first gate.
Press PG1:
Press PG1 whe-
Press PG1 to
the gate starts
re you want to
stop the move-
the closing
start the slowing
ment in the ope-
ning operation.
operation.
operation.
Press PG1 to stop the
movement of the first gate
and PG2 to stop the se-
cond gate.
Press PG2 to stop the
movement of the second
gate and PG1 to stop the
first gate. END
Press PG1 to stop the
movement in the
closing operation.
END