GB
1 2 3 4 5
6
7
8
9
10 11
BUTTON P1
RADIO PROG button for the storage of the
transmitters
BUTTON P2
TIME PROG button for the storage of the opera-
ting time
TECHNICAL SPECIFICATIONS
Voltage
Power
Accessory alimentation output
Automatic closing time
Operating time
Courtesy light time
Number of codes
Transmitters
Frequency
Operating temperature
Sensibility
Homologation
MACH2 230
INSTRUCTIONS:
CRX
L1
T1
T3
T2
L3
P2
SELECTION
OPTIONS 1-8
PG2
25 26 27 28 29
PG2
L4 L5
L6 L7 L8 L9 L10
12 13 14 15 16 17 18 1920 21 22 23 24
PG1 BUTTON
GATE 1 button for the storage of the travel of
the first gate
PG2 BUTTON
GATE 2 button for the storage of the travel of
the second gate
TRIMMER T1
220V AC +/- 10%
The Power Trimmer regulates the pair and the sen-
550 W
sitivity in normal operation.
12/24V AC 250mA
5 a 120 sec
TRIMMER T2
3 a 120 sec
The Power Slow Trimmer regulates the pair and the
180 sec
sensitivity in slowing.
254 codes
Fix\Rolling code
-
+
433.92 / 868 Mhz
-20 a 70° C
–100dBm
TRIMMER T3
Conf ETS 300-220/ETS
The Break Trimmer regulates the pause time from 3
300-683
to 120 sec
Terminals
Type
Description
1 - 2
220V ~ LINE input 220VAC
3 - 4
220V ~ FLASHING LIGHT input
3 - 5
220V ~ COURTESY LIGHT input
6- 7- 8com
220V ~ MOTOR 1 input (6-7 input phases with a capacitor in parallel)(8 common)
9-10-11com 220V ~ MOTOR 2 input (9-10 input phases with a capacitor in parallel)(11 common)
L2
12 - 14com
NC
LIMIT SWITCH CLOSING contact Mot. 2 (If you do not use it, please insert the jumper)
P1
13 - 14com
NC
LIMIT SWITCH OPENING contact Mot. 2 (If you do not use it, please insert the jumper)
15 - 17com
NC
BAND/PHOTOCELL OPENING contact (If you do not use it, please insert the jumper)
J1
16 - 17com
NC
PHOTOCELL CLOSING contact (If you do not use it, please insert the jumper)
19 - 18com
NC
LIMIT SWITCH CLOSING contact Mot.1 (If you do not use it, please insert the jumper)
20 - 18com
NC
LIMIT SWITCH OPENING contact Mot.1 (If you do not use it, please insert the jumper)
21 - 23com
NC
STOP contact (If you do not use it, please insert the jumper)
PG1
22 - 23com
NO
PEDESTRIAN START contact
24 - 23com
NO
START contact (Alternate Pulse OPEN/STOP/CLOSE/STOP)
25 - 27com
24V ~
Photocells + accessories 24VAC 250mA
26 - 27com
12V ~
Photocells + accessories 12VAC 250mA
28 - 29
12Vdc
Electrolock power
30 - 31
ANTENNA input (30 joiner / 31 signal)
JUMPER J1
Radio memory internal or external. Possibility to insert an external radio receiver by connector CRX to
increase the codes number or the change of frequency.
Insert jumper:
internal
LED READING
L1
L2
L3
L4
L5
L6
L7
L8
L7+L8
L9
L10
external
STATUS Led
On when the control panel is powered
RADIO Led
On when you log in the radio memory
PROGRAMMING TIME Led
The led flashes during the programming
PHOTOCELL 2 Led CLOSING
On when the limit switch is in N.C.
PHOTOCELL 2 Led OPENING
On when the limit switch is in N.C.
PHOTOCELL Led CLOSING
On when the safety contact is off
PHOTOCELL 1 Led CLOSING
On when the limit switch is in N.C.
PHOTOCELL 1 Led OPENING
On when the limit switch is in N.C.
STOP Led
Both on when the stop is in N.C.
PEDESTRIAN Led
On when you give a pedestrian pulse
START Led
On when you give a pulse
v E 01022012