Burner and nozzle specifications
Table 1
Burner
Diameter
(mm)
100
Rapid (R)
75
Semi Rapid (S)
55
Auxiliary (A)
Supply pressures
*
At 15°C and 1013,25 mbar - dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m
A
R
S
S
TQG 641 /A(ICE)
TQG 641 /A(BK)
Liquid Gas
Thermal Power
By-pass
Nozzle
kW (p.c.s.*)
1/100
1/100
(mm)
Nomin. Reduc.
0.70
39
3.00
0.40
28
1.65
0.40
28
1.00
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
3
Natural Gas
Flow*
Nozzle
g/h
1/100
(mm)
(mm)
***
**
86
218
214
116(Y)
64
120
118
96(Z)
50
73
71
79(6)
28-30
37
20
25
35
45
Flow*
l/h
286
157
95
20
17
25
GB