CLEANING AND MAINTENANCE - Water drainage
The device has an internal water collection tray. When it is full, the device stops functioning and the indication
light lights up on the control panel at "WATER FULL".
1. Turn off the device and pull the plug from the
socket.
2. Place the device on an elevation, and place a
bucket or other kind of collection tray underneath
the drain hole of the water collection tray.
3. Unscrew the lid and plug of the drain hole (figure
1, No. 12), see figure 6. The water streams from
the water collection tray in the bucket.
4. If the water collection tray is empty, put the lid
and plug back in the drain hole, and make sure
it is properly closed.
ATTENTION:
Carefully move the device and keep it upright at all times, to prevent spillage of the water over the brim
of the internal water collection tray. During emptying, you can slant the device slightly to remove the last
water from the water collection tray.
If the bucket, or other kind of collection tray, cannot collect all the water at the same time, put the lid and
plug of drain hole back. Empty the bucket and repeat the steps.
Continuous drainage
If you often use the device to dehumidify the air, you can also use the continuous drainage.
1. Turn off the device and pull the plug from the
socket.
2. Unscrew the lid and plug from the continuous
drain hole (figure 1 No. 6), see figure 7.
3. Connect a drainage hose (not included) to the
continuous drain hole (zie figuur 7), and make
sure the end of the hose is placed in a bucket,
or other kind of collection tray.
4. Use the device as prescribed in this manual.
CLEANING AND MAINTENANCE - Cleaning the filter
For an optimal result, you have to clean the 4 filters every two weeks, and replace at least 1x per year, or
more often if the filter is visibly full. Also clean the filter before you store it for longer periods of time, or when
you use it again after a long time.
1. Turn off the device and pull the plug from the socket.
2. Remove the filter from the back of the device
(see figure 8).
3. Rinse the filter with lukewarm water, or have
it soak in soapy water.
4. Let the filter dry properly.
5. Put the cleaned (or new) filter back in the device.
ATTENTION:
If the filter has not dried properly, water can enter the
device. This could cause (electrical) damage.