FP SERIES PUMP
TROUBLESHOOTING
Problem
Insufficient water
coming out of
the pump
The pump stops
working
Check that the rotor
doesn't have any
obstructions
W A T E R G A R D E N I N G T O T H E M A X
Check that the pump intake is clean and without any obstructions
Check that there are no kinks in the connected tubes
Check that the pump is correctly powered.
Make sure that the water level is not too low. The intake tube of the pump must be
below the water level both on submerged and external applications.
FP550/750
The pump is provided with a self-resetting thermal protector.
If the pump stopped working, please investigate if the thermal cut-off has been
activated by first disconnecting the appliance from the electrical supply for
approximately 1 hour, then remedy the cause that made the appliance stop, and
reconnect to the socket again.
FP1150/1550/2050
The pump is provided with SmartMAG® motor protection. If there is lack of water or the
rotor is blocked the pump recognizes the problem and turns off and attempts to restart.
After 10 restart attempts (FP1150/1550) or 5 restart attempts (FP2050) in the space of
1 minute, the pump turns off completely. In this case unplug the pump from the electrical
outlet and remove the cause of the problem. After adding water or clearing the blocked rotor
plug the pump back in which will reset the SmartMAG® and the pump will resume working.
W A T E R G A R D E N I N G T O T H E M A X