1. Inspect cord and plug for damage.
2. Visually inspect the HEPA Filter for damage, punctures or tears. If you are operating in or exhausting into a highly
sensitive area it is strongly recommended that this unit is independently tested to assure proper filtration
efficiencies.
3.
Inspect and tighten the HEPA filter hold down nuts, which may have loosened during transportation of the unit.
1. Always handle this unit with care. Rough handling such as dropping, or tipping over the unit, bouncing around in a
vehicle, and impact from rolling over or off of curbs, stairs and other platforms, could cause serious damage to
this unit.
2.
Always clean and decontaminate unit before storing it. Store this unit indoors in a dry location.
PROBLEM
Machine will not start
Machine will not run
Continuously
No power to GFCI outlet control panel
CLEAN AIR EXHAUST DISCHARGE
This portable air scrubber allows the operator to connect a 12"
exhaust hose to the unit allowing for remote or controlled exhausting
and/or to create a controlled negative pressure in a contained area.
Simply connect a 12" hose (#860243) to the 12" exhaust flange
located on the back/exhaust end of unit and extend the hose to the
desired area you wish to exhaust to.
AIR INTAKE FLANGE
This scrubber also has an air intake flange, which allows the operator
to connect a 12" hose and place the open end of the hose in a
contaminated area and the air scrubber in another remote area.
BEFORE OPERATING THE UNIT
TRANSPORTING AND STORING UNIT
TROUBLE SHOOTING
POSSBILE CAUSE
Power cord unplugged
Blown or tripped circuit breaker
Tripped thermal protector on
motor
Tripped ground fault
Motor speed control set to low
Not enough amperage
Extension cord too long or
inappropriate gauge.
Tripped GFCI on control panel
5
REMEDY
Plug cord into outlet
Replace/reset building fuse or
breaker
Turn off unit and let cool for
Approximately 20 minutes, then
turn back on.
Push reset button on the GFCI located
on the control panel
Start motor in highest speed position
then lower speed after start-up
Use a larger circuit or remove
other appliances from circuit
Use a 12 gauge extension cord
Maximum length 50'
Reset the breaker on the GFCI