Télécharger Imprimer la page

Nikro Industries PS600 Mode D'emploi page 4

Publicité

Les langues disponibles

Les langues disponibles

Your #PS600 Poly Air Scrubbing System has been thoroughly tested and inspected at the factory and is fully assembled
and ready for use. However, prior to plugging the unit in, inspect it for any damage that may have occurred during
shipping. Inspect and tighten the HEPA filter hold down nuts, which may have loosened during transportation.
ELECTRICAL RATING:
115V
3 Amps
60 HZ
FILTER SET-UP PROCEDURES
The Model #PS600 Air Cleaning unit is equipped with three stages of filtration as follows:
#860958 1" Polyester Filter Pad (1
ST
Stage)
nd
#860959 2" Pleated Filter (2
Stage)
#862074 H.E.P.A. Filter (99.97% efficient @ 0.3 microns) (Final Stage)
The H.E.P.A. Filter is held in place by 4 nuts and 2 – hold down brackets.
Slide the brackets over the threaded mounting studs located on the inside
of the housing. Thread the nuts over the brackets and tighten securely with
a 1/2" wrench. Be sure these nuts & brackets are always tightened
securely on the frame of the HEPA filter to guarantee a tight seal with the
H.E.P.A. Filter and the filter frame of the unit. The air flow arrows on this
filter should always be directed towards the motor and blower assembly.
Always turn off and unplug unit when removing or replacing the H.E.P.A.
filter. (See Photo 1)
The 2" Pleated Filter should be set in front of the H.E.P.A. Filter. The air
flow arrows on this filter should always be directed towards the H.E.P.A.
Filter. (See Photo 2)
The 1" Polyester Filter Pad should be placed in the door frame of the unit.
Close the hinged door of the unit and snap the latches into the locked
position...Unit is ready for use. (See Photo 3 & 4)
An optional Carbon Filter can be used to help control odors.
Simply replace the #860959 – 2" Pleated Filter with #860960 – 2" Carbon
Filter (sold separately).
FILTER MAINTENANCE
When performing filter maintenance always wear proper personal protective equipment and clothing. Always follow safe
working practices including proper disposal and handling of used filters in accordance with all federal, state and local
regulations.
The model #PS600 Air Cleaning unit is equipped with a Filter-Monitor gauge. This gauge is located on the control panel of
the unit. When gauge reads 2" or higher (in highest speed position), filter maintenance is required and the following steps
should be taken:
1. Change the 1" Polyester Filter pad (this filter cannot be cleaned or reused. Dispose of Properly)
2. Close cabinet door and turn unit on.. If gauge continues to read 2" (in highest speed position) or higher go to step #3
3. Change the 2" Pleated Filter (this filter cannot be cleaned or reused. Dispose of Properly)
4. Close cabinet door with all filters in proper position. Turn unit on. If gauge continues to read 2" or higher (in highest
speed position), the H.E.P.A. Filter must be replaced. (This filter cannot be cleaned or reused. Dispose of Properly)
NOTE: FILTERS SHOULD BE REPLACED IMMEDIATELY IF TORN OR DAMAGED.
USE OF ANY OTHER FILTERS THAN ORIGINAL NIKRO REPLACEMENT PARTS VOIDS THE PRODUCT
WARRANTY AND PERFORMANCE CLAIMS
TO AVOID CROSS CONTAMINATION CHANGE ALL FILTERS AFTER EVERY REMEDIATION JOB AND CLEAN
ENTIRE UNIT THOROUGHLY BEFORE REMOVING IT FROM THE CONTAINMENT AREA.
4

Publicité

loading