Télécharger Imprimer la page

Beko CWB 6441 BN Manuel D'utilisation page 6

Masquer les pouces Voir aussi pour CWB 6441 BN:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
WARNINGS - COMPONENTS
WARNINGS
This appliance has been designed for use as either an EXTRACTION (ducting to the outside) or RECIRCULA-
TION (filtering) hood. The measurements contained on the drawings in this booklet refer to two models of cooker
hood. Therefore, it is essential that you refer to the correct drawing when taking measurements for installation.
- The minimum distance between the cooking surface and the metal grease filters on the underside of the
hood must be 650mm.
- This cooker hood must be installed in accordance with the installation instructions and all requirements
must be adhered to.
- If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating
boiler then its flue must be of the room sealed or balance flue type.
- If other types of flue or appliances are fitted ensure that there is an adequate supply of air to the room.
- When the range hood and appliance supplied with energy other than electricity are simultaneously in op-
eration, the negative pressure in the room must not exceed 4 Pa (4x10
- The ducting system for this appliance must not be connected to any ventilation system which is being used
for any other purpose.
- The ducting system for this appliance must not be connected to any existing ventilation system which is
being used for any other purpose.
- Do not leave naked flames or carry out flambè cooking under this cooker hood.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or in-
struction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance
CONNECTING THE POWER CABLE TO THE MAINS POWER SUPPLY
Before installation, check that the mains voltage indicated on the rating plate inside the appliance corresponds to the
voltage available in your home. If the Hood is not fitted with a plug have a licensed electrician, fit the power cable
with a plug of a type approved for the load indicated on the rating plate; when connecting directly to the mains, insert
an omni polar circuit breaker with a minimum contact aperture of 3mm and a size suitable for the load in question
between the appliance and the mains supply, making sure it is of a type that complies with current regulations.
COMPONENTS
- 2 No Wall Brackets C
- 1 No 150-120mm Ducting Spigot G
- 1 No Air Outlet Connection H (Optional)
- 2 No Charcoal Filters L (Optional)
EN
-5
bar).
6 6

Publicité

loading

Ce manuel est également adapté pour:

Cwb 6441 xnCwb 6441 xnaCwb 6441 bnaCwb 6441 wn