CAUTION !
To reduce the risk of fire, electric shock or injury to persons
during the installation and use of your pump, it is recommended that basic safety precautions should always be taken, including
the following precaution:
Read all these instructions before starting to operate this product and keep these instructions in a safe place.
1) GENERAL
The JET pump has been designed to suck up clear water.
It should be installed in a location that is dry, ventilated and protected from bad weather and heat. The maximum suction height
should not exceed 8 meters.
Correctly installed, your pump will function with maximum, output and should meet your requirements fully: read the following
Instructions carefully.
2) TECHNICAL CHARACTERISTICS
Model
JET 61
Type
Self-priming
Max suction
8 m
Output
38 l/min at 5 m
Discharge
10l/min at 15 m
Motor power
600 W
Power supply
230 V/ 50Hz
Speed
2850
(rotations / minute)
3) INSTALLATION
a) Important recommendations;
Before connecting to the electrical supply, you must:
Fix the pump firmly to the ground or onto a suitable support. To do this, there are two notches provided for this purpose
in the foot of the pump for securing it with bolts (not supplied).
Check that the mains supply corresponds to that given on the pump's technical table.
WARNING
The warranty does not cover accidents due to poor installation. This pump should be installed according to the national
standards in force (NFC 15100 for France) and by qualified personnel. We advise you to call in an electrician.
The fixed pipe works to which the pump will be connected must have a separation device with contacts of at least 3mm
opening distance at all poles.
If the pump is used for swimming pools it must be powered by a transformer with circuit breaker (RCCD) with sensitivity
not exceeding 30mA. The pump should not be used in outside fountains, garden ponds and similar places.
N.B.:
This pump is not intended for cleaning or other maintenance operations on swimming pools. When it is used for swimming
pools, it must be installed in an enclosed service area.
The total manometric height should not-exceed 35m. The connection cable should be at least of the type H05RNF-3x1mm
neutral and earth).
User and Maintenance Manual
(Pump JET61 / JET81 / JET 101/ JET101I / JET121)
JET 81
Self-priming
8 m
28 l/min at 8m
24l/min at 15m
750 W
230 V/ 50Hz
2850
GB
JET 101/JET101I
JET 121
Self-priming
Self-priming
8 m
8 m
33 l/min at 8m
35 l/min at 8m
28 l/min at 15m
31 l/min at 15m
970 W
1180 W
230 V/ 50Hz
230 V/ 50Hz
2850
2850
6
2
(live,