Télécharger Imprimer la page

Metabo HPT G 12VE2 Instructions De Sécurité Et Mode D'emploi page 14

Publicité

Les langues disponibles

Les langues disponibles

English
Reattaching procedure (Fig. 9)
(1) Engage the clip on the side fi lter with the vent air hole
and align the fi lter with the main unit.
(2) Insert the bottom fi lter, then push in the clips with the
side fi lters.
NOTE
○ When detaching the fi lter, be careful not to let debris
enter the tool body.
○ Keep the fi lter set attached except during cleaning or
replacement.
8. Maintenance of the motor
The coil on the motor is an important part of the unit.
Make sure that it is not damaged or subject to oil or
water.
NOTE
In order to expel debris and dust, periodically run the
motor with no load.
CAUTION
In the operation and maintenance of power tools,
the safety regulations and standards prescribed
in each country must be observed.
14
Fig. 9

Publicité

loading

Ce manuel est également adapté pour:

G 13ve2