D
o not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
T
he appliance must be stored in a room without continuously operating ignition sources(for examples: open flames, an operating gas appliance
or an operating electric heater).
D
o not pierce or burn.
B
e aware that refrigerants may not contain an odour.
If
the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
T
his appliance can be used by children aged 8 years and above and persons with reduced physical,sensory or mental capabilities or lack of
experience and knowledge if they have been given superivision or instruction concering use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
T
he wiring method should be in line with the local wiring standard.
A
ll the cables shall have got the European authentication certificate. During installation, when the connecting cables break off, it must be
assured that the grouding wire is the last one to be broken off. The explosion-proof breaker of the air conditioner should be all-pole switch.
Distance between it's two contacts should not be no less than 3mm. Such means for disconnection must be incorporated in the wiring.
M
ake sure installation is done according to local wiring regulation by professional persons.
M
ake sure ground connection is correct and reliable. A leakage explosion-proof breaker must be installed.
T
he installation and service of this product shall be carried out by professional personnel, who have been trainedand certified by national training
organizations that areaccredited to teach the relevant national competency standards that may be set in legislation.
M
echanical connectors used indoors shall comply with ISO 14903. When mechanical connectors are reused indoors, sealing parts shall be
renewed. When flared joints are reused indoors, the flare part shall be re-fabricated.
T
his appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons。
D
isconnect the appliance from its power source during service and when replacing parts
T
he maximum working pressure is 4.15 MPa.This maximum working pressure shall be considered when connecting the outdoor unit to indoor
units.
T
he refrigerant suitable for the indoor unit is R410A. The indoor unit shall only be connected to outdoor unit suitable for the same refrigerant.
T
he unit is a partial unit air conditioner, complying with partial unit requirements of the International Standard, and must only be connected to
other units that have been confirmed as complying to corresponding partial unit requirements of the International Standard.
T
he A-weighted sound pressure level is below 70 dB.