USE
A:
if it is turned on, the compressor is powered. If it flashes, the cell setpoint is changing or compressor protection is in progress.
B:
if it is on, the defrosting, pre-dripping or dripping phase is in progress. If it is flashing: defrosting has begun but the compressor
is being protected or the compressor is running until the minimum temperature for defrosting is reached.
C:
if it is lit, the evaporator fan powered.
If it is flashing, the evaporator fan is stopped where provided (e.g. defrosting).
D:
if lit, it indicates that the control unit is powered, but is in stand-by.
E:
if it is lit, the compressor has run for the set number of hours and requires service from a qualified technician for condenser
cleaning and to check correct operation.
Some general information
The panel has a 3-digit and 4-key display: SET, UP, DOWN, ON/STAND-BY/DEFROST
The panel can be in three different conditions:
on
•
= the panel is powered and on. The display will show the temperature of the cell, except during defrosting, when the instrument
will display the set temperature before defrosting is activated or the T° setpoint value + 4°C.
stand-by
•
= the panel is powered, but it is off
off
•
= the panel is not powered.
In case of alarm or error, the panel emits a sound, to stop it, simply press any key.
panel off
Maximum operating temperature: 43 °C
A
B
C
ON/STAND-BY
SET
panel in stand-by
E
DOWN
UP/DEFROST
panel on
29
D