Installation, Maintenance, and Repair Manual
Series 800M4, LF800M4
Pressure Vacuum Breaker Assemblies
" – 2"
1
2
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
Local building or plumbing codes may require modifications
to the information provided. You are required to consult the
local building and plumbing codes prior to installation. If
the information provided here is not consistent with local
building or plumbing codes, the local codes should be
followed. This product must be installed by a licensed
contractor in accordance with local codes and ordinances.
Need for Periodic Inspection/Maintenance: This product
must be tested periodically in compliance with local codes,
but at least once per year or more as service conditions
warrant. All products must be retested once maintenance
has been performed. Corrosive water conditions and/or
unauthorized adjustments or repair could render the product
ineffective for the service intended. Regular checking and
cleaning of the product's internal and external components
helps assure maximum life and proper product function.
Freeze sensor solely provides alerts about a possible freeze
event and cannot prevent a freeze event from occurring.
User action is required to prevent freeze conditions from
causing product and/or property damage.
For Australia and New Zealand, line strainers should be
installed between the upstream shutoff valve and the inlet of
the backflow preventer.
If installed on a fire sprinkler system, all mechanical checks,
such as alarm checks and backflow preventers, should be flow
tested and inspected internally in accordance with NFPA 13
and NFPA 25.
Testing
For field testing procedure, refer to Watts installation sheets
IS-TK-DL, IS-TK-9A, IS-TK-99D, and IS-TK-99E at
www.watts.com.
For other repair kits and service parts, refer to the Backflow
Prevention Products Repair Kits & Service Parts price list
PL-RP-BPD at www.watts.com.
For technical assistance contact your local Watts representative.
800M4FR-FZ
Series 800M4 and LF800M4 antisiphon PVBs (FR and QT
versions) are ideal for continuous pressure health hazard
applications where exposure to sudden freezing conditions may
occur, particularly in irrigation systems and industrial process
water systems.
Both series include a sensor for use with SentryPlus Alert
technology to monitor temperature and alert facility personnel when
freeze conditions can cause damage to equipment. (The sensor
is installed on the assembly exterior and does not alter assembly
functions or certifications.) The monitoring system is compatible
with BMS and irrigation management systems, allowing freeze
alerts to be distributed according to the BMS or IMS application.
When the monitoring system is Wi-Fi enabled, notifications can be
issued through the Smart Freeze Alert cloud service.
An add-on connection kit (sold separately) is required to activate
the freeze sensor. Without the connection kit, the sensor is
a passive component that has no communication with any
other device. (The kit can also be used to install an alternative
standalone outdoor sensor or to retrofit existing installations. See
"Add-on/Retrofit Sensor Connection Kit," for ordering details.)
Use of the freeze sensor and activation kit with FZ models does
not replace the need to comply with all required instructions,
codes, and regulations related to installation, operation, and
maintenance of the PVB assembly.
Watts is not responsible for the failure of alerts due to connectivity
issues, power outages, or improper installation.
RP/IS-800M4
®

Publicité

loading

Sommaire des Matières pour Watts 800M4 Serie

  • Page 1 PVB assembly. IS-TK-DL, IS-TK-9A, IS-TK-99D, and IS-TK-99E at www.watts.com. Watts is not responsible for the failure of alerts due to connectivity For other repair kits and service parts, refer to the Backflow issues, power outages, or improper installation.
  • Page 2 (See Water Figure 3.) The hydrant is connected to the PVB assembly and Supply installed through the structure wall to connect to the water supply. Watts TWS Drain Port or Blow Down...
  • Page 3 Servicing and Maintenance Internal parts can be removed, repaired, or inspected without removing the valve from the piping. Routine Service 1. In cold climates, open the test cocks to drain if operated only seasonally. 2. Replace rubber goods every 5 years. Vacuum Breaker Disassembly 1.
  • Page 4 Limited Warranty: Watts (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.
  • Page 5 à l’entretien de l’ensemble de casse-vide à pression. 99E sur le site www.watts.com. Watts n’est pas responsable de la défaillance des alertes due à Pour les autres trousses de réparation et pièces de rechange, des problèmes de connectivité, à des coupures de courant ou à...
  • Page 6 LF800M4FR. Vous pouvez Robinet de vidange également utiliser l’enceinte isolée WattsBox. Pour plus de de sortie renseignements, téléchargez ES-WB sur le site watts.com. Dégagement minimum de • Suivre la norme ASSE 1020 afin que la vanne de mise à l’air 12 po (30,5 cm)
  • Page 7 Entretien et maintenance Il est possible de retirer, réparer ou inspecter certaines pièces intérieures sans avoir à retirer la vanne de la tuyauterie. Procédure de service de routine 1. Dans les climats froids, ouvrez les robinets d’essai pour les purger s’ils ne fonctionnent que de façon saisonnière. 2.
  • Page 8 Garantie limitée : Watts (la « Société ») garantit que chacun de ses produits est exempt de vice de matériau et de fabrication dans des conditions normales d’utilisation pour une période d’un an à compter de la date d’expédition d’origine. Si les défauts susmentionnés venaient à se présenter au cours de la période sous garantie, la Société pourrait, à sa discrétion, être amenée à remplacer le produit ou le remettre en état, sans frais.
  • Page 9 Para otros kits de reparación y piezas de repuesto, consulte Watts no es responsable de la falla de las alertas debido a los kits de reparación de productos para prevención de flujo de problemas de conectividad, cortes de energía o instalación retorno y la lista de precios de piezas de servicio PL-RP-BPD en incorrecta.
  • Page 10 • Proteger del congelamiento. Para protección contra conge­ lamiento, especifique Modelo 800M4FR o LF800M4FR. O bien, considere el gabinete aislado WattsBox. Para obtener Figura 2 más información, descargue ES-WB en watts.com. Válvula de drenaje de salida • Siga la norma ASSE 1020 que indica que la válvula de ven­...
  • Page 11 Servicio y mantenimiento Las piezas internas pueden retirarse, repararse o inspeccionarse sin quitar la válvula de la tubería. Servicio de rutina 1. En climas fríos, abra las llaves de prueba para drenar si se operan solo por temporada. 2. Reemplace los productos de caucho cada 5 años. Desmontaje del disyuntor de vacío 1.
  • Page 12 Garantía limitada: Watts (la “Compañía”) garantiza que cada producto está libre de defectos en los materiales y la mano de obra en condiciones de uso normal en el período de un año a partir de la fecha de envío original. En caso de que tales defectos se presenten dentro del período de garantía, la Empresa, a su criterio, reemplazará o reacondicionará el producto sin cargo alguno.

Ce manuel est également adapté pour:

Lf800m4 serie