Télécharger Imprimer la page

Hilti DD 110-D Mode D'emploi page 32

Masquer les pouces Voir aussi pour DD 110-D:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 50
7.7
Switching off
The core bit is filled with dust and drilled-out material. Allow for the extra weight in the core bit and
make sure you have a firm stance before you remove the core bit from the drillhole.
1. Switch off the diamond core drilling machine.
2. Withdraw the core bit from the hole as the machine slows down, but before it stops.
3. If you were using a vacuum cleaner, switch it off.
8
Care and maintenance
WARNING
Electric shock hazard! Attempting care and maintenance with the supply cord connected to a power outlet
can lead to severe injury and burns.
▶ Always unplug the supply cord before carrying out care and maintenance tasks.
Care
Carefully remove stubborn dirt from the tool.
Clean the air vents carefully with a dry brush.
Use only a slightly damp cloth to clean the casing. Do not use cleaning agents containing silicone as
they can attack the plastic parts.
Maintenance
WARNING
Danger of electric shock! Improper repairs to electrical components may lead to serious injuries including
burns.
▶ Repairs to the electrical section of the tool or appliance may be carried out only by trained electrical
specialists.
Check all visible parts and controls for signs of damage at regular intervals and make sure that they all
function correctly.
Do not operate the product if signs of damage are found or if parts malfunction. Have it repaired
immediately by Hilti Service.
After cleaning and maintenance, fit all guards or protective devices and check that they function correctly.
To help ensure safe and reliable operation, use only genuine Hilti spare parts and consumables. Spare
parts, consumables and accessories approved by Hilti for use with the product can be found at your
local Hilti Store or online at: www.hilti.group.
8.1
Replacing the carbon brushes
WARNING
Risk of injury due to electric shock !
▶ The machine may be operated, serviced and repaired only by trained, authorized personnel. This
personnel must be specially informed of any possible hazards.
1. Open the carbon brush covers on the left-hand and right-hand side of the motor.
2. Take note of how the carbon brushes are fitted and how the conductors are positioned. Remove
the worn carbon brushes from the diamond core drilling machine.
3. Fit the new carbon brushes so that they are positioned exactly the same as the old ones fitted previously.
Take care to avoid damaging the insulation on the indicator lead as you insert the brushes.
4. Close the carbon brush covers on the left-hand and right-hand side of the motor and tighten the retaining
screws.
26
English
7
274860
*274860*

Publicité

loading