INDICATIONS FOR TERMINAL CONNECTION
Clos 2000-1
Clos 2000-4
Clos 2000-2
Clos 2000-6
Clos 2000-3
A
1
2
Terminal 1
1
To be connected to the "EARTH" connexion.
Terminal 2
2
To be connected to the fence as "TOTAL POWER OUTPUT".
Terminal 3
3
As an option, to be connected to the fence as "REDUCED POWER
OUTPUT" as well as the return signal test.
BAR-GRAPH INDICATIONS
Clos 2000-4 LED
Clos 2000-6 LED
BACKLIGHT = GREEN when all is well.
BACKLIGHT = FLASHING RED when the voltage is no longer sufficient to guard, or if a
fault is found by the Sentinel. In this case the element is in error at the flashing display.
Clos 2000-4 LED
A
1
2
Clos 2000-6 D
V out ≥ 7 000 V
V out ≥ 6 000 V
V out ≥ 5 000 V
V out ≥ 4 000 V
V out ≥ 3 000 V
V out ≥ 2 500 V
V out ≥ 2 000 V
V out ≥ 1 500 V
BAR-GRAPH OPERATION
INDICATOR OF THE FENCE.
Each LED indicates a level of
the output voltage (V out) of the
energizer.
Led alarm :
V out < 1 500 V
Clos 2000-6 LED
A
1
2
DIGITAL DISPLAY INDICATIONS
Clos 2000-6 D
Voltage reading by each
Sentinel responder
when installed
(1)
— 11 - § EN —
Clos 2000-6 D
B
3
1
Lamp A
A
Pilot lamp
Lamp B
B
Return signal LED
Voltage output Display
(1)
Connexion example with a Sentinel
responder : next page
A
B
2
3