Télécharger Imprimer la page

United States Stove Company Ashley AP5622 Manuel D'instructions Et D'utilisation Du Propriétaire page 11

Publicité

INSTALLATION
This appliance is certified for use with listed 3 inch
or 4 inch "PL" pellet venting products. The use of
other components other than stated herein could
cause bodily harm, heater damage, and void your
warranty.
HORIZONTAL EXHAUST VENT
INSTALLATION
1.
Locate your pellet stove in a location which
meets the requirements of this manual, but
in an area where it does not interfere with the
house framing, wiring, etc.
2. Install
a
non-combustible
underneath the pellet stove. This pad should
extend at least 6" (152 mm) in front of the unit.
3. Place the pellet stove approximately 15" (381
mm) away from the interior wall.
4. Locate the center of the exhaust pipe of your
unit. This point should then be extended to
the interior wall of your house. Once you have
located the center point, on the interior wall, cut
a 7" (175 mm) diameter hole through the wall.
5. The next step is to install the wall thimble, refer
to the instructions which come with the wall
thimble for this step.
6. Install the appropriate length of exhaust vent
pipe into the wall thimble. See steps 11 and 12
when determining the correct length of exhaust
vent to use.
Outside Fresh Air is Mandatory when
7.
installing this pellet stove room heater
in
airtight
homes
transportable buildings. Be sure that the
outside air vent has an approved cap on it
to prevent rodents from entering. Be sure
to install in location that won't become
blocked with snow, etc.
8. Connect the exhaust vent pipe to the exhaust
outlet of your pellet stove.
9. Secure all vent joint connections with 3 screws.
Seal the exhaust vent joint connections with
high temperature silicone sealant.
10. Push the unit straight back to the interior
wall, being sure to maintain the minimum
clearances to combustibles 2" (51 mm) to the
back of the unit. Seal the annular space of the
wall thimble and around the vent pipe with
high temperature silicone sealant.
hearth
pad
and
mobile
home/
11. The exhaust vent pipe must extend at least 12"
(300 mm) out past the exterior wall. Seal the
annular space of the wall thimble and around
the vent pipe with high temperature silicone
sealant.
12. Install an approved horizontal termination cap or
if necessary install a 90° elbow and appropriate
length of vertical venting. An approved vertical
vent cap is recommended.
THROUGH THE WALL INSTALLATION
(RECOMMENDED INSTALLATION)
TO STOVE
Canadian installations must conform to CAN/
CSA-B365. To vent the unit through the wall,
connect the pipe adapter to the exhaust motor
adapter. If the exhaust adapter is at least 18" (457
mm) above ground level, a straight section of
pellet vent pipe can be used through the wall.
Your heater dealer should be able to provide you
with a kit that will handle most of this installation,
which will include a wall thimble that will allow
the proper clearance through a combustible
wall. Once outside the structure, a 3" (76 mm)
clearance should be maintained from the outside
wall and a clean out tee should be placed on the
pipe with a 90-degree turn away from the house.
At this point, a 3ft (0.91m) (minimum) section of
11
© 2024 United States Stove Company
90° Elbow
Termination
Cap
Support
Bracket
Exhaust Motor
Adapter
Pipe
Adapter
Wall
Thimble
Tee
Clean-Out
Cover
Non-Combustable
Floor Pad

Publicité

loading