Model
Max. efficiency [%]
Euro. efficiency [%]
Standby consumption
[W] @Night
Ingress protection
Protective class
Overvoltage category
Operating ambient temperature
range [°C]
Max. operation altitude [m]
Humidity [%]
Typical noise emission [dB]
Storage temperature [°C]
Dimensions(W×H×D) [mm]
Weight [kg]
Cooling concept
Communication interfaces
Optional monitoring dongle
Over/under voltage protection
DC isolation protection
Monitoring ground fault
protection
Grid monitoring
DC injection monitoring
Back feed current monitoring
Residual current detection
Anti-islanding protection
Over temperature protection
SPD (PV/AC)
AFCI
Safety
EMC
Grid monotoring
Inverter typology
Active anti-islanding method
Micro-breaker
Note:
1. For X1-MINI-3.7K-G4 and X1-MINI-4.0K-G4, internal fan is standard.
X1-MINI-
X1-MINI-
2.0K-G4
2.5K-G4
98
98
97
97
25
25
5.5
5.5
RS485/DRM/USB/Heat Pump, Optional: CT/Meter
EN61000-6-1/2/3/4;EN61000-3-2/3/11/12
IEC61727, EN50549, G98, AS 4777.2, VDE4105, CEI 0-21, VFR
16A
20A
X1-MINI-
X1-MINI-
3.0K-G4
3.3K-G4
98
98
97
97
<1
IP66
I
II (DC), III (AC)
-25-60
<4000
0-100
25
25
-30-70
290x206x120
5.5
5.5
Nature cooling
Pocket WiFi/LAN/4G
YES
YES
YES
YES
YES
YES
YES
YES
YES
Type II (Optional)
Optional
EN/IEC62109-1/2
Non-isolated
Frequency shift
20A
20A
X1-MINI-
X1-MINI-
3.7K-G4
4.0K-G4
98
98
97
97
30
30
5.5
5.5
25A
25A
75