Model
Max. output apparent power [VA]
Max. output continuous
current [a.c.A]
Nominal AC voltage [a.c.V]/
Grid range
Nominal grid frequency [Hz]
Displacement power factor
ITHDi (rated power) [%]
Current (inrush) [a.c.A]
Maximum output fault current
[a.c.A]
Maximum output overcurrent
protection [a.c.A]
• System Data, Protection and Standard
Model
Max. efficiency [%]
Euro. efficiency [%]
Standby consumption
[W] @Night
Ingress protection
Protective class
Overvoltage category
Operating ambient temperature
range [°C]
Max. operation altitude [m]
Humidity [%]
Typical noise emission [dB]
Storage temperature [°C]
Dimensions(W×H×D) [mm]
Weight [kg]
Cooling concept
Communication interfaces
Optional monitoring dongle
Over/under voltage protection
DC isolation protection
Monitoring ground fault protection
Grid monitoring
DC injection monitoring
Back feed current monitoring
Residual current detection
Anti-islanding protection
Over temperature protection
SPD (PV/AC)
AFCI
Safety
EMC
Grid monotoring
Inverter typology
Active anti-islanding method
Micro-breaker
74
X1-MINI-
X1-MINI-
2.0K-G4
2.5K-G4
2200
2750
10
12.5
X1-MINI-
X1-MINI-
0.6K-G4
0.7K-G4
98
96
25
5.2
5.2
RS485/DRM/USB/Heat Pump, Optional: CT/Meter
EN61000-6-1/2/3/4;EN61000-3-2/3/11/12;EN55011
IEC61727, EN50549, G98, AS 4777.2, VDE4105, CEI 0-21, VFR
X1-MINI-
X1-MINI-
3.0K-G4
3.3K-G4
3300
3300
15
15
220/230/240; 90-290
50/60; ±5
0.8leading-0.8lagging
<3
50
58 (15 ms)
35
X1-MINI-
0.8K-G4
98
98
96
95
<1
IP66
I
II (DC), III (AC)
-25-60
<4000
0-100
25
25
-30-70
290x206x120
5.2
Nature cooling
Pocket WiFi/LAN/4G
YES
YES
YES
YES
YES
YES
YES
YES
YES
Type II (Optional)
Optional
EN/IEC62109-1/2
Non-isolated
Frequency shift
10A
X1-MINI-
X1-MINI-
3.7K-G4
4.0K-G4
4070
4400
18.5
20
X1-MINI-
X1-MINI-
1.1K-G4
1.5K-G4
98
98
97
97
25
25
5.2