APPLIANCE INSTALLATION INSTRUCTIONS
To keep the temperature of the stove's surrounding walls down to 65°C above ambient, the minimum distances shown on the
diagram below must be adhered to.
If the surrounding walls are made from incombustible materials and are not susceptible to degradation under heat (wall temperatures up
to 200°C), this clearance can be reduced to 150mm
Side
wall
Concrete plinth size 100cm x
100cm x 45mm thick, covered by
a metal plate with an upward-
facing reflective surface (stainless
steel or gloss ceramic)
XD le 18/02/2020
SEDAN S stove
PLAN VIEW OF STOVE INSTALLATION
550
mm
Back
wall
550
mm
Reference: P9450/ver1.1
Back wall
550mm
Stainless
steel
sheet
Concrete
plinth