3.
After having fitted the float make sure that the cable is protected and made safe along its entire length.
4.
The float switch must change the contact at least 15 cm before the foot valve (pump suction valve) takes in air.
WARNING
MAKE SURE THAT THE SYSTEM IS CORRECTLY SECURED TO THE WALL
5.
Start-up
Check the following points before start-up:
Check that the system is securely fixed and that the safety screws have been fastened.
•
Ensure that the power supply is switched off, signalled and locked open, e.g. with a padlock.
•
All hydraulic connections must be tight.
•
All electrical connections must be checked.
•
See also section 6 for the pump's control panel use instructions.
Proceed as follows:
Start-up with mains water
1.
Open the mains water pipe on-off valve, the tank starts to fill.
2.
Remove the pump filler plug and fill it with water, replacing the plug once full.
3.
Open the delivery on-off valve.
4.
Make sure that there are no leaks in the hydraulic system.
5.
Plug the power supply into an outlet properly protected by a differential circuit breaker (residual current
detector).
The pump starts and the green led for power lights.
6.
The pump automatically turns off after 15-20 seconds if all the taps on the system are closed.
Start-up with water from the collection tank
Start-up with water from the collection tank is only possible if the float switch inside the collection tank is in the up
position.
6.
Pump control panel
Control panel description.
6.1. Start up
The green Power on LED will light up on the control panel and the pump will start (yellow Pump on LED lit up)
and keep running for several seconds to start up the system.
If this time is insufficient, the device will stop the pump (red Failure LED blinking).
Keep the Restart button pushed in until the red Failure LED turns off and the water comes out of the opened tap.
When the tap is closed the pump will stop after a few seconds (yellow Pump on LED turns off).
From now on the device will turn the pump on and off depending on the opening and closing of the tap.
ENGLISH
Figure 07
25
1.
Power ON: Green LED lit,
device live
2.
Pump ON: Yellow LED lit,
pump running
3.
Failure: Red LED flashing, no
water
4.
Restart: Press to reset after a
fault
5.
Restarting pressures
6.
SET button