· The appliance must not be positioned directly underneath socket-outlet.
WARNING
·
: In order to avoid a hazard for very young children, this appliance
should be installed so that the lowest heated rail is at least 600 mm above the floor.
· Appliance is to be supplied through a residual current device (RCD) having a
rated residual operating current not exceeding 30 mA.
· Means for disconnection having a contact separation in all poles must be
incorporated in the fixed wiring in accordance with the wiring rules.
CAUTION
·
: in order to avoid a hazard due to inadvertent resetting of the thermal
cutout, this appliance must not be supplied through an external switching
device, such as a timer, or connected to a circuit that is regularly switched on
and off by the utility.
INSTALLATION
Before the installation, please make sure to meet the below requirements:
• The control panel must be in the bottom position.
• The distance between the bathtub and the appliance should be at least 60cm.
• The distance between the ceiling and the appliance should be at least 15cm.
• The distance between the ground and the appliance should be at least 15cm.
WARNING: In order to avoid a hazard for very young children, its recommended install this appliance so that
the lowest heated rail is at least 60 cm above the floor.
EN
WARNING this product shall be
installed only in the volumes 2
& 3 of a bathroom according the
>15cm
rules of standard installation.
We suggest you to contact
a professional electrician for
assistance.
>15cm
WARNING: The installation of
this appliance on the wall of a
bathroom always must be done at
a distance where no person in the
shower or in the bath may touch it
or switch it on.