1. Technical data / tool components
Air inlet inside thread
Weight
Recommended hose Ø air
Recommended hose Ø water
Air requirement
Working pressure
Temperature range
1
Water regulator
2
Air regulator
3
System cleaning nozzle
4
Washing nozzle
5
3/4" GHT thread
6
Component adapter (1/2 "/ ø13)
• Effective flushing - without use of chemicals
• Multi-functional - replaceable nozzles
• Individual control of both air and water flow
• Great mobility
; Güldenwerther Bahnhofstraße 25 - 29 • 42857 Remscheid • GERMANY
[ +49 (0) 21 91 / 7 92-0 • \ +49 (0) 21 91 / 7 92-375 • ^ hazet.de • ] info@hazet.de
3
Design and function
mm (")
kg
mm
mm
L/min
bar
PSI
°C
4
HAZET-WERK Hermann Zerver GmbH & Co. KG
Always wear personal protective equipment!
Included in delivery
9048 P-2/3
• 1 x Cooling system flusher
12.91 (1/4")
0.40
• 1 x system cleaning nozzle
10
• 1 x washing nozzle
13
200
6 - 10
87 - 154
-10 / +40
3
6
360°
including connection
nipple
1
2
max.
5 Nm
5
17