Technical Data - Kuppersbusch IKE 1870-1 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Problem
The temperature in the
appliance is too high.
Replacing the lamp
1. Disconnect the mains plug from the
mains socket.
2. Remove the screw from the lamp cov-
er.
3. Remove the lamp cover (refer to the il-
lustration).
4. Replace the used lamp with a new
lamp of the same power and specifical-
ly designed for household appliances.
(the maximum power is shown on the
lamp cover).
5. Install the lamp cover.
6. Tighten the screw to the lamp cover.
7. Connect the mains plug to the mains
socket.
8. Open the door. Make sure that the
lamp comes on.

Technical data

Dimension of the recess
Rising Time
Voltage
Frequency
Possible cause
The temperature regulator is not
set correctly.
The door is not closed correctly.
The product temperature is too
high.
Many products are stored at the
same time.
There is no cold air circulation in
the appliance.
Height
Width
Depth
Set a lower temperature.
Refer to "Closing the door".
Let the product temperature de-
crease to room temperature be-
fore storage.
Store less products at the same
time.
Make sure that there is cold air
circulation in the appliance.
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to
"Installation".
3. If necessary, replace the defective door
gaskets. Contact the Service Center.
1030 mm
560 mm
550 mm
12 h
230-240 V
50 Hz