OPERATION
TLC
5
1
4
2
3
1: + motor
2: On/Off motor
3: - motor
4: On/Off light
5: Led
Note: the LED on the hood indicates the various speeds: green 1st speed, orange 2nd speed, red
3rd speed and flashing red 4th speed. „If the remote control unit is changed, the appliance must be
reset to the frequency of the new unit as follows:
1. Disconnect the power supply to the hood.
2. Wait 5 seconds and then switch the power
supply on again.
3. Within the first 5 seconds, press the button for the
lights and release it when the lights come on.
4. Within 5 seconds, press and release the motor
button.
You will then need to wait for about 10 seconds, after which the hood can be used as normal.
Whenever the power supply is disconnected, you must wait for 10 seconds before using the
extractor."
Note: 4 hours after the last key touch, the fan will automatically turn off.
All hoods with capacities exceeding 650 m3/h have the last timed speed; It lasts for 7 minutes, after
which it automatically returns to the last non-timed speed.