MOUNTING AND OPERATION
Action
Fitting and adjusting the wheel
guard
Fixing the side handle
Assembling depressed center
wheel
Assembling cutting wheel
Switch operation
Grinding angle and grinding
method
Selecting accessories
MAINTENANCE AND INSPECTION
1. Inspecting the depressed center wheel
Ensure that the depressed center wheel is free of cracks
and surface defects.
2. Inspecting the mounting screws
Regularly inspect all mounting screws and ensure that
they are properly tightened. Should any of the screws be
loose, retighten them immediately. Failure to do so could
result in serious hazard.
3. Inspecting the carbon brushes
For your continued safety and electrical shock protection,
carbon brush inspection and replacement on this tool
should ONLY be performed by a HiKOKI AUTHORIZED
SERVICE CENTER.
4. Replacing supply cord
If the replacement of the supply cord is necessary, it
has to be done by HiKOKI Authorized Service Center to
avoid a safety hazard.
5. Maintenance of the motor
WARNING
Always wear protective goggles and dust respirators
when blowing air from the tail cover air hole with the use
of an air gun, etc.
Failure to observe this may result in ejected dust being
inhaled or entering your eyes.
The motor unit winding is the very "heart" of the power tool.
Exercise due care to ensure the winding does not become
damaged and/or wet with oil or water.
NOTE
When work has been fi nished, blow air containing no
moisture from the tail cover air hole with the use of an
air gun, etc., while running the motor without any load
applied. This is eff ective in removing any dirt and dust
that has accumulated. Dirt and dust collecting inside the
motor may result in malfunctions.
CAUTION
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
GUARANTEE
We guarantee HiKOKI Power Tools in accordance with
statutory/country specifi c regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling instruction,
to a HiKOKI Authorized Service Center.
IMPORTANT
Correct connection of the plug
Figure
Page
The wires of the main lead are coloured in accordance
with the following code:
1
134
2
134
As the colours of the wires in the main lead of this tool may
3
135
not correspond with the coloured markings identifying the
terminals in your plug proceed as follows:
4
135
The wire coloured blue must be connected to the terminal
marked with the letter N or coloured black. The wire
5
135
coloured brown must be connected to the terminal marked
with the letter L or coloured red. Neither core must be
6
136
connected to the earth terminal.
NOTE:
137
This requirement is provided according to BRITISH
STANDARD 2769: 1984.
Therefore, the letter code and colour code may not be
applicable to other markets except The United Kingdom.
Information concerning airborne noise and vibration
The measured values were determined according to
EN60745 and declared in accordance with ISO 4871.
Measured A-weighted sound power level: 97 dB (A).
Measured A-weighted sound pressure level: 86 dB (A).
Uncertainty K: 3 dB (A).
Wear hearing protection.
Vibration total values (triax vector sum) determined
according to EN60745.
Surface grinding:
Vibration emission value
Uncertainty K = 1.5 m/s
The declared vibration total value has been measured in
accordance with a standard test method and may be used
for comparing one tool with another.
It may also be used in a preliminary assessment of exposure.
WARNING
○ The vibration emission during actual use of the power
○ Identify safety measures to protect the operator that
NOTE
Due to HiKOKI's continuing program of research and
development, the specifi cations herein are subject to
change without prior notice.
6
Blue: — Neutral
Brown: — Live
a
,
h
2
tool can diff er from the declared total value depending in
the ways in which the tool is used.
are based on an estimation of exposure in the actual
conditions of use (taking account of all parts of the
operating cycle such as the times when the tool is
switched off and when it is running idle in addition to the
trigger time).
= 9.3 m/s
2