Change the Sear Burner Orifice
1.
Use a screwdriver to remove screw from the ignitor pin
and disconnect the searing burner ignitor wire.
2.
Remove two screws on the rear of the searing burner.
Lift the burner starting from the back.
3.
Use 6 mm socket wrench or 6 mm nut driver to remove
the orifice. Replace with the Natural gas orifice.
IMPORTANT: Check that the orifice is properly installed
inside of the valve.
4.
Reinstall the sear burner. Tighten the two screws on the
rear of the sear burner.
5.
Reinstall the ignitor pin.
6.
Position the igniter so that it is 3.18 mm / 1/8 in. away
from each burner.
7.
Open the manual shutoff valve in the gas supply. The
valve is open when the handle is parallel to the gas pipe.
8.
Test all connections using an approved noncorrosive
leak- detection solution. Bubbles will show a leak.
Correct any leak found.
9.
For normal operating sequence of the ignition system,
see "Lighting Instructions" on page 9.