Visual indication
2 flashes
4 4
3 flashes
4 4 4
4 flashes
4 4 4 4
5 flashes
4 4 4 4 4
6 flashes
4 4 4 4 4 4
7 flashes
4 4 4 4 4 4 4
8 flashes
4 4 4 4 4 4 4 4
9 flashes
4 4 4 4 4 4 4 4 4
10 flashes
4 4 4 4 4 4 4 4 4 4
ECO 3 - 3R - 3RL / ECO 5 - 5R / ECO 7 - 7R
3
2
1
1009DIS391
INDEX
1
Components Plate
2
Electromagnetic Valve
Connection Flange
3
Photoresistance
4
5
Release Button
6
Electrodes set
7
Nozzle Line (with Preheater Mod. R)
Automatic air flap
8
DIAGNOSIS OF LMO EQUIPMENT FAULTS AND LOCK OUT
Description of operating anomalies
Possible causes
No flame signal
Faulty fuel valves
-
Faulty flame detector
-
Incorrect burner setting, no fuel
-
No ignition
-
Not used
Stray light on ignition
Not used
Not used
No flame signal during operation
Faulty fuel valves
-
Faulty flame detector
-
Incorrect burner setting, no fuel
-
Anomalies in fuel preheating time
Not used
Incorrect electrical connection or damage to equipment
MAIN COMPONENTS
4
5
6 7
16
15
13
14
12
9
Control box
10 Pump
11 Motor
12 Body
13 Fan
14 Deflector
15 Transformer
16 Draught tube
8