Télécharger Imprimer la page

Publicité

Liens rapides

Save these instructions. This manual will help you to obtain
efficient, dependable service from the heater, and enable
you to order repair parts correctly. Keep in a safe place for
If this heater is not properly installed, a house fire may result.
For your safety, follow the installation instructions. Never
use make-shift compromises during the installation of this
heater. Contact local building or fire officials about permits,
restrictions and installation requirements in your area.
Please read this entire manual before you install or use your
new room heater. Failure to follow instructions may result in
property damage, bodily injury, or even death. Improper
Installation Could Void Your Warranty!
Owner's Manual Model: VG1120
future reference.
SAFETY NOTICE:
CAUTION!
United States Stove Company
PO Box 151, 227 Industrial Park Rd.,
South Pittsburg, TN 37380
PH: (800) 750-2723
www.usstove.com
Report Number: F19-473
Tested Per EPA Methods ALT-125, ASTM
E2515, ASTM E3053 and CSA B415
Certified to UL 1482-2011 (R2015) and
ULC-S627-00 (R2016)
Approved for mobile home installation
in USA and Canada
U.S. Environmental Protection Agency
Certified to comply with 2020
Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de
particulate emissions standards.
carbone, lesquels sont reconnus dans l'État de la Californie comme causant le cancer et
des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de
renseignements, veuillez consulter le site www.P65warnings.ca.gov
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon monoxide, which
is known to the State of California to cause cancer, birth defects and/or other
reproductive harm. For more information, go to www.P65warnings.ca.gov
R
853522B-4203i

Publicité

loading

Sommaire des Matières pour VOGELZANG VG1120

  • Page 1 Owner’s Manual Model: VG1120 Save these instructions. This manual will help you to obtain efficient, dependable service from the heater, and enable you to order repair parts correctly. Keep in a safe place for future reference. Report Number: F19-473 SAFETY NOTICE: Tested Per EPA Methods ALT-125, ASTM If this heater is not properly installed, a house fire may result.
  • Page 2 This manual describes the installation and operation of the Vogelzang, VG1120 wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s cordwood emission limits for wood heaters sold after May 15, 2020. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 15,196 to 40,594 Btu/hr with 1.7 g/hr and 69% efficiency.
  • Page 3 Assembly UNPACK AND INSPECT Remove the packing from the appliance and inspect for any damage. Your appliance is packed with the door handle spring not installed. Ensure that the bricks are positioned correctly and not broken (see illustration for proper brick arrangement). Make sure that the baffle board, above the air tubes, is in place and undamaged. (DO NOT REMOVE).
  • Page 4 Installation SAFETY NOTICE • IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. • CONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS AND INSTALLATIONS REQUIREMENTS IN YOUR AREA. •...
  • Page 5 CLEARANCES TO COMBUSTIBLES It is of utmost importance that the clearances to combustible materials be strictly adhered to during installation of the stove. Refer to the provided tables: Backwall Ceiling Backwall CORNER INSTALLATION CORNER INSTALLATION CLEARANCE TO CLEARANCE TO WALLS CLEARANCE TO WALLS WALLS &...
  • Page 6 • Your stove does not draw steadily, smoke rollout occurs, wood burns poorly, or back-drafts occur whether or not there is combustion present. • Existing fuel-fired equipment in the house, such as fireplaces or other heating appliances, smell, do not operate properly, suffer smoke roll-out when opened, or back-drafts occur whether or not there is combustion present.
  • Page 7 CHIMNEY CONNECTOR (STOVE PIPE) The chimney connector and chimney must have the same diameter as the stove outlet (6”). If this is not the case, we recommend you contact your dealer to ensure there will be no problem with the draft.
  • Page 8 FACTORY BUILT CHIMNEY When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed. You must also purchase (from the same manufacturer) and install the ceiling support package or wall pass-through and “T” section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended by the manufacturer.
  • Page 9 COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS METHOD A - 12” (304.8 mm) Clearance to Combustible Wall Le dégagement minimum de la cheminée à la brique et les Member: Using a minimum thickness 3.5” (89 mm) brick matériaux combustibles est de 5 cm (2 po) (50,8 mm) and a 5/8”...
  • Page 10 Operation WOOD STOVE UTILIZATION The operation of this wood heater in a manner inconsistent with the owner’s manual will void your warranty and is also against federal regulations. This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods or too green or freshly cut hardwoods.
  • Page 11 It is EXTREMELY IMPORTANT to use DRY WOOD only in your wood stove. The wood should have dried for 9 to 15 months, such that the humidity content (in weight) is reduced below 20% of the weight of the log. It is very important to keep in mind that even if the wood has been cut for one, two or even more years, it is not necessarily dry, if it has been stored in poor conditions.
  • Page 12 negative pressure in the house. If such is the case, open a window slightly near the stove and twist together a few sheets of newspaper into a torch. Light up this paper torch and hold it as close as possible to the mouth of the pipe inside the combustion chamber to warm up the chimney.
  • Page 13 RELOADING Once you have obtained a good bed of embers, you should reload the unit. To do so, open the air controls to maximum a few seconds before opening the stove’s door. Then proceed by opening the door very slowly; open it one or two inches for 5 to 10 seconds, before opening it completely to increase the draft and thus eliminate the smoke which is stagnant in a state of slow combustion in the stove.
  • Page 14 Maintenance Your wood stove is a high-efficiency stove and therefore requires little maintenance. It is important to perform a visual inspection of the stove every time it is emptied, to ensure that no parts have been damaged, in which case repairs must be performed immediately. Inspect and clean the chimney and connector pipe periodically for creosote build-up or obstructions.
  • Page 15 Optional B36 Blower Wiring Diagram DANGER: SHOCK HAZARD DISCONNECT CAUTION: MOVING PARTS CAN CAUSE POWER SOURCE BEFORE INSTALLATION AND INJURY. DO NOT OPERATE WITH COVER WHENEVER SERVICING BLOWER ASSEMBLY. REMOVED. WHITE / BLACK / BLACK / BLANC NOIR NOIR BLACK / BLACK / BLACK / NOIR...
  • Page 16 Replacement Parts Key Part No. Description 29139 Air Deflector 891824 Heatshield Weldment 40292A 6” Flue Collar 88042 1/4” Rope Gasket 610934 Pedestal Weldment (VG1120-BP) 610918 Access Panel (VG1120-BP) 29055 Ashpan 610944 Ashpan Housing Weldment 610883 Leg Weldment (VG1120-BL) 610928 Damper Weldment...
  • Page 17 Replacement Parts Part No. Description Qty. 893156 Wooden Thru Handle 893071 Door Handle 40881 Medium Sq Cast Door 88324 3/4 Round Rope Gasket-Blk 893154 Glass 29211 Left Side Glass Clamp 29210 Glass Clamp, Bottom 29231 Right Side Glass Clamp 29230 Gasket Clamp 892294 Hinge Pin...
  • Page 18 Service Record It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions. Always use the manufacturer's specified spare part when replacement is necessary.
  • Page 19 HOW TO ORDER REPAIR PARTS / COMMANDE DE PIÈCES DE RECHANGE THIS MANUAL WILL HELP TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND WILL ENABLE THE CORRECT REPAIR PARTS TO BE ORDERED. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE AT- TACHED TO THE BACK OF THE HEATER.