Télécharger Imprimer la page

Danby Premiere DPACIOO6I Manuel D'utilisation page 6

Appareil de confort au foyer portable

Publicité

Les langues disponibles

Les langues disponibles

External Water Tank Feature:
This unit is equipped with an external water tank
which sits on a support tray and is easily attached to
the rear side of the unit with the use of the two
support hangers (see pg. 12). Align the two
supports brackets on the external water tank with
the support hangers on the rear side of the unit and
push down firmly. We recommend the external water
tank be connected to the main unit at all times
during both air conditioning and dehumidifying
modes.
It is possible to operate the unit utilizing the
internal water reservoir only. However, running
timeloperation maybe reduced during high
humidity conditions as (excess) condensed
water accumulates in the internal reservoir only.
Alternatively, when the external water tank is
attached, (excess) condensed water is directed
first into the internal reservoir and once full, will
then be pumped into the external tank, this
results in longer (uninterrupted) running times.
External Water Tank Instructions:
1. Align the holes in the water tank support tray
(A) with the screws (B) located at the rear lower
section of the unit, push down firmly to lock
the tray into position. See
.
35
2. Position the external water tank, making sure the
inlet on the water tank is aligned with water outlet
at the back of the cabinet. See Fig 36.
Water
Inlet
.
3. To make the connection, simply push the water
tank down firmly onto the support hangers on the
back of the cabinet and the water tank support tray.
IMPORTANT: Once external water tank is installed,
ensure that the support brackets located on the water
tank are flush with the back of the unit, then secure the
tank in place with the locking mechanism (Fig. 37)
located above the water outlet. Please note: When the
tank is installed, the lock and unlock symbols will be
hidden
-
Pull the lock lever to the far right in order to lock
the tank into postion, and push the lever to the far left to
unlock the tank (in order to remove it).
4. Install both covers on the water tank.
5. To release (disconnect) the external water tank,
firstly unlock the tank (see above) and grasp the
recessed handles located on each side, pull
up and remove.
Internal Safety Feature
This unit is equipped with a fail-safe switch
mechanism which prevents the unit from condensing
water in the event the external tank is not being
utilized and the internal reservoir becomes full. If this
situation occurs, the unit will signal (BEEP) for 20
seconds, and the (RED) WATER FULL indicator light
will flash. This condition will remain steady until the
external water tank is re-installed (connected) to the
unit, at which time the secondary pump will activate
and pump the water from the internal reservoir to the
external tank allowing normal operation to resume.
IMPORTANT: If the red water full indicator on the
control panel lights up and remains steady does not
flash, ensure the external water tank is connected
(and empty), then proceed to turn off the power to the
unit and temporarily disconnect the power cord. After
several seconds reconnect the power cord, switch to
air conditioning mode and turn the power to the unit
back on, this will pump any excess water out of the
internal system into the external tank allowing normal
operating conditions to continue.
Fig.37
CAUTION
• Always empty the external water tank before
attempting to move or re-locate the unit to another
location.
• In order to avoid spillage when emptying the external
water tank, remove cover "A" (as identified in fig. 36)
and carefully tilt the uncovered portion of the external
tank towards the sink.
Fig.35
External
Water
Tank LOC.ZOutlet
5

Publicité

loading

Ce manuel est également adapté pour:

Dpaci20068Dpac10071