tion.
• Electric Connection:
Note! Verify the data label placed inside the appliance:
- If the symbol
appears on the plate, it means that
no earth connection must be made on the appliance,
therefore follow the instructions concerning insulation
class II.
- If the symbol
DOES NOT appear on the plate, follow
the instructions concerning insulation class I.
Insulation class II
- The appliance has been manufactured as a class II,
therefore no earth cable is necessary.
The plug must be easily accessible after the instal-
lation of the appliance. If the appliance is equipped
with power cord without plug, a suitably dimensioned
omnipolar switch with 3 mm minimum opening be-
tween contacts must be fitted between the appliance
and the electricity supply in compliance with the load
and current regulations.
- The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral.
Insulation class I
This is a class I, appliance and must therefore be con-
nected to an effiecient earthing system.
- The appliance must be connected to the electricity
supply as follows:
BROWN = L line
BLUE = N neutral
YELLOW/GREEN =
earth.
The neutral wire must be connected to the terminal
with the N symbol while the YELLOW/GREEN, wire
must be connected to the terminal by the earth
symbol
.
When connecting the appliance to the electricity
supply, make sure that the mains socket has an earth
connection. After fitting the ducted cooker hood, make
sure that the electrical plug is in a position where it
can be accessed easily. If the appliance is connected
directly to the electricity supply, an omnipolar switch
with a minimum contact opening of 3 mm must be
placed in between the two; its size must be suitable
for the load required and it must comply with current
legislation.
• The minimum distance between the support surfaces
of the cooking pots on the cooker top and the lowest
part of the cooker hood must be at least 65 cm. If a
connection tube composed of two parts is used, the
upper part must be placed outside the lower part. Do
not connect the cooker hood exhaust to the same
conductor used to circulate hot air or for evacuating
fumes from other appliances generated by other
than an electrical source. Before proceeding with the
assembly operations, remove the anti-grease filter(s)
(Fig. 8) so that the unit is easier to handle.
- In the case of assembly of the appliance in the suction
version prepare the hole for evacuation of the air.
• We recommend the use of an air exhaust tube which
has the same diameter as the air exhaust outlet hole.
If a pipe with a smaller diameter is used, the efficiency
of the product may be reduced and its operation may
become noisier.
• Fixing to the wall:
- Drill the holes A respecting the distances indicated
(Fig.2).
- Fix the appliance to the wall and align it in horizontal
position to the wall units.
- When the appliance has been adjusted, definitely fix
the hood using the screws A (Fig.4).
For the various installations use screws and screw
anchors suited to the type of wall (e.g. reinforced
concrete, plasterboard, etc.). If the screws and screw
anchors are provided with the product, check that
they are suitable for the type of wall on which the
hood is to be fixed.
• Fixing the decorative telescopic flue:
- Arrange the electrical power supply within the
dimensions of the decorative flue. If your appliance is
to be installed in the ducting version or in the version
with external motor, prepare the air exhaust opening.
- Adjust the width of the support bracket of the upper
flue (Fig.3).
- Then fix it to the ceiling using the screws A (Fig.3)
in such a way that it is in line with your hood and
respecting the distance from the ceiling indicated in
Fig.2.
- Connect the flange C to the air exhaust hole using a
connection pipe (Fig.4).
- Insert the upper flue into the lower flue.
- Fix the lower flue to the hood using the screws B
provided (Fig.4), extract the upper flue up to the
bracket and fix it with the screws B (Fig.3).
To transform the hood from a ducting version into a
filtering version, ask your dealer for the charcoal filters
and follow the installation instructions.
USE
MECHANICAL CONTROLS (Fig.5)
A: Turn the knob clockwise from position 0 to 1
switch on the light
B: Display to view choosen speed
C: Turn knob clockwise from the position 0 (OFF) to
switch on the hood (speeds from 1 to 3)
MAINTENANCE
•Use only a damp doth with neutral liquid detergent.
•Do not use wet sponges or cloths, water jets,
thinners, solvents, hydrochloric acid, bleach, alcohol
or abrasive substances.
•Unplug the appliance or switch off the circuit breaker
before carrying out maintenance operations.
LED Replacement (Fig.6)
•If the appliance version is with LED lamps, the
intervention of a specialised technician is necessary
to replace them.
Filters Replacement
•ACTIVATED CARBON FILTERS (Only filtering types)
(Fig. 7):
- The filter assembly can not be regenerated and
must be replaced at least every two months.
•METALLIC ANTI-GREASE FILTERS (Fig. 8):
- The filters must be washed at least one a month
with hot water and detergent.
- It can also be washed in the dishwasher.
- Open by means of the handle.
- 6 -