Installation
What's in the Box
Make sure all the following items are included in the
packaging. If any items are damaged or missing, contact your
dealer.
● 12V RV Range Hood
● Mounting Screws (4 pieces)
● Instruction Manual
● Warranty Leaflet
The installation should conform to these installation
instructions and with the standards for recreational vehicles,
NFPA 1192.
IMPORTANT
Observe all governing codes and ordinaces.
It is the installer's responsibility to comply with installation
clearances specified on the model/serial/rating plate. The
model/serial/rating plate is located inside the range hood;
Range hood location should be away from strong draft
areas, such as windows, doors, and strong heating vents.
Models that are capable of being installed as non-vented
(recirculating) require charcoal filters.
WARNING
Installation of this appliance must be made in accordance
with the written instructions provided in this manual. No
agent, representative or employee of Furrion or other
persons has the authority to change, modify or waive any
provision of the instructions contained in this manual.
Range Hood Installation
Disconnect power.
WARNING
Electrical Shock Hazard.
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
Electrical Requirements
Observe all governing codes and ordinaces.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA
70 (lastest edition), or CSA Standards C22.1-94, Canadian
Elec trical Code, Part 1 and C22.2 No. 0-M91 (lastest edition)
and local codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Wire sizes and connections must confirm with the rating of
the appliance as specified on the model/serial/rating plate.
The model/serial/rating plate is located inside the range
4
hood. Wire sizes must confirm to the requirements of the
National Electrical Code, ANSI/NFPA 70 (lastest edition), or
CSA Standards C22.1-94, Canadian Electrical Code, Part 1
and C22.2 No. 0-M91 (lastest edition) and local codes and
ordinances.
Recreational vehicle fan units.
Do not operate any fan with a damaged cord or plug. Discard
fan or return to an authorized service facility for examination
and/or repair.
Product Dimensions (Fig. 1)
Fig. 1
1. Take out the range hood from box and put on a flat surface
with the grill cover facing up.
2. Press the two release tabs on the grill cover to release it
from range hood. (Fig. 2)
Fig. 2
3. Mark centerline of range hood on the cooktop. (Fig. 3)
NOTE: The minimum vertical distance to combustible
material above the cooktop is 191/2 inches when installed
with a range hood, provided the overhead construction
does not extend 13 inches from the rear wall. (Fig. 4)
This range hood will work with Furrion cooktops and
ranges with up to 22,500 BTU.
4³⁄4"
Fig. 3
3³⁄4"
⁵⁄8"
Range Hood
10⁷⁄8"
Outline
19¹⁄2"
23⁹⁄16"
Center of
Range Hood

Publicité

loading

Ce manuel est également adapté pour:

Fho23sacrv-ssFho23sacrv-bp