Problem and alarm code
The appliance does not drain the wa‐
ter.
The indicator
termittently.
Acoustic signal sounds 2 times in‐
termittently.
The anti-flood device is on.
The indicator
termittently.
Acoustic signal sounds 3 times in‐
termittently.
Malfunction of the water level detection
sensor.
The indicator
termittently.
Acoustic signal sounds 4 times in‐
termittently.
Malfunction of the wash pump or the
drain pump.
The indicator
termittently.
Acoustic signal sounds 5 times in‐
termittently.
The temperature of the water inside
the appliance is too high or malfunction
of the temperature sensor occurred.
The indicator
termittently.
Acoustic signal sounds 6 times in‐
termittently.
Technical malfunction of the appliance.
The indicator
intermittently.
Acoustic signal sounds 12 times in‐
termittently.
The level of water inside the appliance
is too high.
The indicator
intermittently.
Acoustic signal sounds 15 times in‐
termittently.
flashes 2 times in‐
flashes 3 times in‐
flashes 4 times in‐
flashes 5 times in‐
flashes 6 times in‐
flashes 12 times
flashes 15 times
Possible cause and solution
Make sure that the sink spigot is not clogged.
Make sure that the interior filter system is not
clogged.
Make sure that the drain hose has no kinks or
bends.
Close the water tap.
Make sure that the appliance is correctly instal‐
led.
Make sure the baskets are loaded as instructed
in the user manual.
Make sure that the filters are clean.
Switch the appliance off and on.
Switch the appliance off and on.
Make sure that the temperature of the inlet wa‐
ter does not exceed 60°C.
Switch the appliance off and on.
Switch the appliance off and on.
Switch the appliance off and on.
Make sure that the filters are clean.
Make sure that the outlet hose is installed at the
right height above the floor. Refer to the installa‐
tion instructions.