CONNECTIONS FOR PERFORMANCE CHECKS
NOTES:
1. REGULATION AND RIPPLE METERS MUST NOT BE GROUNDED THROUGH THREE WIRE LINE CORD TO GROUND.
2. PERFORM CHECKS WITH LOCAL SENSING CONNECTIONS ONLY.
3. DIAGRAM IS SHOWN FOR 230VAC. FOR OTHER VOLTAGES, CONNECT THE NEUTRAL LEAD TO THE APPROPRIATE
"N" CONNECTION ON THE INPUT TERMINAL.
4. POWER SUPPLY IS SUPPLIED WITH 3.15A FUSE FOR 85~132VAC OPERATION. 2A FUSE FOR 170~265VAC
OPERATION IS SUPPLIED IN THE PACKAGE.
SAFETY INSTRUCTIONS
1. FUSE RATING: T3.15A 250V@100/115VAC, T2A 250V@200/230VAC.
2. POWER SUPPLY MUST BE SECURED TO THE CHASSIS OF THE END USE EQUIPMENT BY 4 SCREWS, INSERTED INTO
THREADED HOLES IN THE MOUNTING SURFACE OF THE POWER SUPPLY ENCLOSURE (REFER TO OUTLINE DRWG).
3. MAX. LEAKAGE CURRENT OF THE END USE EQUIPMENT SHOULD NOT EXCEED 3.5mA.
CAUTION: FUSE MUST BE REPLACED BY AUTHORIZED SERVICE PERSONNEL ONLY!
CE MARK
CE Marking when applied to a product covered by this handbook indicates compliance with the Low Voltage Directive (LVD) of the
European Union in that it complies with EN 60950-1.
A "Declaration of Conformity" in accordance with the preceding directive and standard has been made and is on file at our EU
representative TDK LAMBDA UK, located at Kingsley Avenue, Ilfracombe, Devon EX34 8ES, UK.
The latest revision of EU Declaration of Conformity is available via company web site www.uk.tdk-lambda.com/technical-data
SICHERHEITSHINWEISE
VOR ANSCHLUSS AN DAS NETZ AUFSTELLANLEITUNG BEACHTEN!
1. ABSICHERUNG: T3.15A 250V@ 100/115VAG, T2A 250V@200/230VAC.
2. DIE BEFESTIGUNG DES NETZGERAETES IN DER END-ANLAGE ERFOLGT DURCH 4 SCHRAUBEN. IM NETZTEIL EINGESETZTE
EINPRESSMUTTERN AUF DER BEFESTIGUNGSSEITE MUESSEN VERWENDET WERDEN. (SIEHE MASSZEICHNUNG).
3. DER MAXIMALE ABlEITSTROM DER END-ANLAGE DARF 3.5mA NICHT UEBERSCHREITEN.
ACHTUNG
AUSTAUSCH DES SICHERUNGSEINSATZ NUR DURCH GESCHULTES FACHPERSONAL !