Anleitung_SHZ_125_1000_SPK7:_
GB
SHZ 125/250
Voltage (V)
230 V ~ 50 Hz
Rated current (A)
Power consumption (W)
Operating mode
S3 20% 10 min
Rated load (kg)
Lifting height (m)
Rated speed (m/min)
Diameter of steel cable (mm)
Tensile strength of the steel cable (N/mm²)
Insulation class
Protection class
Drive unit class
Net weight (kg)
Maximum number of windings:
Operating mode S3 – 20% - 10 minutes: S3 =
Intermittent mode without influencing the starting
process. This means that the maximum operating
period over a time of 10 minutes is 20% (2 minutes).
SHZ 300-2
Voltage (V)
230 V ~ 50 Hz
Rated current (A)
Power consumption (W)
Operating mode
S3 20% 10 min
Rated load (kg)
Lifting height (m)
Rated speed (m/min)
Diameter of steel cable (mm)
Tensile strength of the steel cable (N/mm²)
Insulation class
Protection class
Drive unit class
Net weight (kg)
Maximum number of windings:
Operating mode S3 – 20% - 10 minutes: S3 =
Intermittent mode without influencing the starting
process. This means that the maximum operating
period over a time of 10 minutes is 20% (2 minutes).
SHZ 500-2
Voltage (V)
230 V ~ 50 Hz
Rated current (A)
Power consumption (W)
Operating mode
S3 25% 10 min
Rated load (kg)
Lifting height (m)
Rated speed (m/min)
Diameter of steel cable (mm)
Tensile strength of the steel cable (N/mm²)
Insulation class
Protection class
Drive unit class
12
16.10.2008
16:07 Uhr
Net weight (kg)
Maximum number of windings:
2,2
500
Operating mode S3 – 25% - 10 minutes: S3 =
Intermittent mode without influencing the starting
125 / 250
process. This means that the maximum operating
11,5 / 5,7
period over a time of 10 minutes is 25% (2.5
8 / 4
minutes)
3,0
1870
SHZ 600
B
Voltage (V)
IP 54
Rated current (A)
M1
Power consumption (W)
10,5
Operating mode
4
Rated load (kg)
Lifting height (m)
Rated speed (m/min)
Diameter of steel cable (mm)
Tensile strength of the steel cable (N/mm²)
Insulation class
Protection class
Drive unit class
Net weight (kg)
2,4
Maximum number of windings:
550
Operating mode S3 – 20% - 10 minutes: S3 =
150 / 300
Intermittent mode without influencing the starting
11,5 / 5,7
process. This means that the maximum operating
8 / 4
period over a time of 10 minutes is 20% (2 minutes).
3,0
1870
SHZ 1000
B
Voltage (V)
IP 54
Rated current (A)
M1
Power consumption (W)
11
Operating mode
4
Rated load (kg)
Lifting height (m)
Rated speed (m/min)
Diameter of steel cable (mm)
Tensile strength of the steel cable (N/mm²)
Insulation class
Protection class
Drive unit class
Net weight (kg)
4,0
Maximum number of windings:
900
Operating mode S3 – 25% - 10 minutes: S3 =
250 / 500
Intermittent mode without influencing the starting
11,5 / 5,7
process. This means that the maximum operating
8 / 4
period over a time of 10 minutes is 25% (2.5
4,2
minutes).
1770
B
IP 54
M1
Seite 12
16,5
4
230 V ~ 50 Hz
4,6
1050
S3 20% 10 min
300 / 600
11,5 / 5,7
8 / 4
4,5
1770
B
IP 54
M1
17,5
5
230 V ~ 50 Hz
7,4
1600
S3 25% 10 min
500 / 999
11,5 / 5,7
8 / 4
5,6
1770
B
IP 54
M1
31
4

Publicité