Télécharger Imprimer la page

Waeco AirCon Service Center ASC2300G Notice D'utilisation page 74

Masquer les pouces Voir aussi pour AirCon Service Center ASC2300G:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 172
Initial start-up
7.6
Editing default values
The AirConServiceCenter has preset values for the most important
service tasks. The default values appear automatically when you select
the respective menu.
You can alter the following default values if necessary:
Parameter
Pressure increase test time min.
Vacuum time min.
Leak test min.
PAG oil ml. (additional quantity)
UV tracer ml.
Filling Qt. g.
Print recovery value?
1. In the basic menu, use the cursor keys  or  to select "Other
selections":
2. Press ENTER to confirm.
3. Use the cursor key  to select "Service".
4. Press ENTER to confirm.
5. Enter the password "7388".
6. Use the keypad and the cursor keys to enter the information.
7. Press ENTER to confirm.
8. Press STOP to access the standby menu.
74
Short selection
Free selection
Other selections
ENTER-OK
AirConServiceCenter
Default value
5
20
4
5
7
500
Yes
EN

Publicité

loading

Ce manuel est également adapté pour:

Aircon service center asc1300gAircon service center asc3300g