AirConServiceCenter
"Vacuum time" indicates how long the vacuum pump was operating in
total.
"Service completed" indicates the amount of service work performed on
the air conditioning service unit.
9.7
Correcting the filling quantity for long service
hoses
I
NOTE
If longer or shorter service hoses are required for the device, you
need to adjust the filling quantities to the new hose lengths.
The service hoses for the high and low pressure sides must always
be of the same length, as otherwise the filling quantities will not be
correctly measured.
1. In the basic menu, use the cursor keys or to select "Other
selections":
2. Press ENTER to confirm.
3. Use the cursor keys or to select "Service":
4. Press ENTER to confirm.
5. Enter the password "7732".
6. Enter the hose length in centimetres.
7. Press ENTER to confirm.
EN
Vacuum time
Total
min.
STOP-EXIT
Service completed:
Total
Total
STOP-EXIT
Short selection
Free selection
Other selections
ENTER-OK
Int. vessel filling
Flushing
Reset scales.
Service.
Service tasks
07/03/14
79
08/03/14
4
105