Sudden drop in gas flow
or reduced flame height
Irregular flame pattern.
Flame is yellow or orange. The new burner may have
34
Out of gas.
Excess flow. Safety device
may have been activated.
Burner ports are clogged
or blocked.
residual manufacturing
oils.
Spider webs or insect nest
in venturi.
Food residue or grease
on burner.
Poor alignment of valve
to injector venturi.
Replace or refill the LP
gas cylinder.
Turn both control knobs
to OFF, wait 30 seconds
and light the barbecue.
If the flames are still low,
reset the safety device
by turning both control
knobs to OFF and the
LP gas cylinder valve to
CLOSED. Disconnect the
regulator.
Turn both control knobs
to HI, wait 1 minute,
then turn them back
to OFF. Reconnect the
regulator and check the
connections for leaks.
Slowly turn the LP gas
cylinder valve to OPEN,
wait 30 seconds and light
the barbecue following
the instructions.
Clean the burner ports.
Let it burn for 15 minutes
with the lid closed.
Clean the venturi.
Clean the burner.
Ensure that the burner
venturi is properly
engaged with the injector.