G1
G5
G4
3.3 Checking for leaks
ATTENTION!
◊ Use a standard leak detecting method to ensure all connections are tight. Never
use an open flame to check for leaks and do not rely on your hearing or smelling.
1.
Set all control knobs to OFF.
2.
Open the gas control valve on the gas cylinder.
3.
Brush a soap solution over all gas system joints including valve connections,
hose connections and regulator connections.
4.
If bubbles form somewhere, it means there is a leak. If the connection is not
sealed, immediately close the cylinder valve by turning the operating lever G2
to the 9 o'clock position.
5.
Tighten the connection or replace the leaking part before using the product.
6.
Repeat the leak test annually or whenever the gas cylinder is repaired or
replenished.
3.4 Using the product
ATTENTION!
◊ During use, the surface of the product becomes very hot. Touch only the handles,
otherwise you may get burned!
1.
Follow the instructions in 3.2 "Connecting the product to the LP gas cylinder"
and 3.3 "Checking for leaks" before using the product.
2.
Open the lid and ensure all knobs are in OFF position.
3.
Turn on the gas cylinder valve.
4.
Push and turn the control knob counterclockwise to the HI position until a click
is heard and the burner is lit.
G2
9
English
31