TOOLS AND MATERIALS NEEDED FOR INSTALLATION
You will need a drill with a 1/8" bit to install sheet metal screws into connector pipe. A 5/16" socket/wrench or
screw driver to install pedestal trim, room air deflector, and blower assembly described below. A 1/2" socket/
wrench to install flue collar. A non-combustible floor protector as specified in this manual. All chimney and chimney
connector components required for your particular chimney installation. For mobile homes, see page 13.
Assembly
Flue Collar Assembly:
1. Mount the flue collar to the top of the unit as shown using the (3) 5/16-18 x 1-1/2 bolts, (3) washers, and (3)
weld tabs provided in the parts box.
Room Air Deflector Assembly:
1. Locate the Room Air Deflector. Using the three(3) 1/2 Tek Screws provided, mount the deflector to the unit
as shown in the diagram.
Firebrick Configuration:
1. Replace the Firebrick as shown in the illustration below.
Side view of flue collar
mount to heater top
REV
DESCRIPTION
A
INITIAL RELEASE
Brick Configuration
SECTION A-A
SCALE .1
-3-
5/16-18 x 1-1/2
BOLT
1
REVISION HISTORY
HEATER
TOP
WELD
TAB
DATE
BY
Date
Who?
B