Télécharger Imprimer la page

Eaton DC1-1D Serie Notice D'installation page 2

Publicité

L1 /L L2 /N
L3
1
2
3
4
5 6
7
8
9 10 11
U
V
W
Mains (TN, TT)
L1
L2
L3
N
PE
TN-S
DC1-12...
Mains, U
= 1 ~ 200 - 240 V ±10 %
LN
L1/L
L1
L2/N
N
PE
EMC Filter
DC1-32...
Mains, U
= 3 ~ 200 - 240 V ±10 %
LN
L1/L
L1
L2/N
L2
L3
L3
PE
EMC Filter
DC1-1DzzzN...
Mains, U
= 1 ~ 110 V
LN
L1/L
L1
L2/N
N
PE
DC+
EMC Filter
2/12
L1
L2
L3
PEN
TN-C
I
e
Motor
U
V
M
3 ∼
W
DC+
BR
Brake chopper
(DC1-3...B-A20...)
FS2, FS3
DC1-34...
Mains, U
= 3 ~ 380 - 480 V ±10 %
LN
I
e
Motor
U
V
M
3 ∼
W
DC+
BR
Brake chopper
(DC1-12...B-A20...)
FS2, FS3
I
e
Motor
U
V
M
230 V
3 ∼
W
BR
Brake chopper
(DC1-1D...NB-A20...)
FS2
Emergency On Call Service: Local representative (www.eaton.eu/aftersales) or +49 (0) 180 5 223822 (de, en)
DC1-x y zzz F N- A20 N
TT
230 V
230 V (U
= 3 ~ 230 V)
LN
400 V (U
= 3 ~ 400 V)
LN
440 - 480 V (U
= 3 ~ 480 V)
LN
N = Standard
CE1 = Coated Board, Enhanced, Version 1
20 = IP20, NEMA 0
B = Brake chopper (DC+, BR)
N = No Brake chopper
F = EMC Filter (RFI)
N = No EMC Filter
I
e
2D2 = 2.2 A
024 = 24 A
U
(Mains), 50/60 Hz
LN
1 = 110 V (110 - 115 V ±10 %)
2 = 230 V (200 - 240 V ±10 %)
4 = 400 V (380 - 480 V ±10 %)
D = Doubler: 110 V (Mains) → 230 V (Motor)
Mains → Motor
1 = 1 AC → 3 AC
3 = 3 AC → 3 AC
L1
L2
L3
N

Publicité