These instructions are part of the Duravit
product and must be read carefully and kept
available at all times.
Target readership and qualifications
The product may only be installed by a
qualified plumber.
Explanation of the symbols
Link to the mounting instructions
in this section
Prompt to inspect
for leaks and leak-tightness
Prompt to wear gloves
Optional settings
Technical data
Operating pressure
Recommended
Test pressure
1 MPa = 10 bar = 145 PSI
Hot water temperature
Safety instructions
Cut and crushing injuries
> Wear gloves when installing the product.
Product and/or property damage
> Observe the local installation regulations
> Equalise pressure differences between cold
> Observe the manufacturer's instructions for
Mounting instructions
max. 1.0 MPa
0.3 - 0.5 MPa
max. 1.6 MPa
max. 60 °C
and any country-specific standards at all
times.
and hot water connections.
installation with continuous flow heaters.
1
Mounting the complete set
> Mount the complete set on BlueBox;
see Duravit instructions MAL # 57112.
5
Using silicone without acetic acid
> Use alkoxy-based silicone.
5