Recommended Mounting Heights
102–152 mm
(4"–6")
Standard Wattage
Height
203–279 mm
(8"–11")
305 mm (12")
Recommended Element Height for the single models in all widths.
381 mm (15")
Standard Wattage
Height
254–356 mm
(10"–14")
533 mm (21")
Recommended Element Height for dual models with a 76 mm (3")
spacer in all widths
457 mm (18")
Standard Wattage
Height
254–356 mm
(10"–14")
610 mm (24")
Recommended Element Height for dual models with a 152 mm (6")
spacer in all widths.
Form No. GRCEM1-1115
Add 76 mm (3")
for units with lights.
High Wattage
Height
279–356 mm
(11"–14")
High Wattage
Height
356–457 mm
(14"–18")
High Wattage
Height
356–457 mm
(14"–18")
7
Minimum Clearance Requirements for
Combustible Surroundings
Models
(A)
GRa and
254 mm
GRaL
(10")
GRaH and
343 mm
GRaHL
(13-1/2")
NOTE: Dual strip heaters cannot be installed in
combustible surroundings.
Pass-Through Shelf
C
Counter
Combustible Clearance Requirements
NOTE: The size of heat patterns vary depending on the height
of the unit.
INSTALLATION
(B)
(C)
76 mm
25 mm
(3")
(1")
76 mm
25 mm
(3")
(1")
B
A