Installing Portable Units
Single strip heater units under 1829 mm (72") long can be
mounted on C-Leg or T-Leg stands for portable use. Portable
units are required to have a power cord and plug connection.
NOTE: C-Legs and T-Legs are not to be used with dual strip
heater units.
C-Leg Stand Mounting
Two types of C-Legs are available.
• CL-Low = 254 mm (10") height, for standard wattage strip
heaters up to 1829 mm (72") in width only.
• CL-High =343 mm (13-1/2") height, for high wattage strip
heaters up to 1829 mm (72") in width only.
CL-Low
283 mm
(11-1/8")
C-Leg Footprint Dimensions
Perform the following procedure to install a C-Leg stand on
each end of the unit.
1. Position the unit upside-down on a flat surface.
2. Install sneeze guard(s), if applicable (refer to the OPTIONS
aND aCCESSORIES section for details on installing a
sneeze guard).
3. Remove the two hanger tab screws and hanger tabs.
4. Remove the one end plate screw that aligns with the
lowest mounting hole on the C-Leg.
5. align the three mounting holes on the C-Leg with the three
holes on the unit. Secure the leg to the unit with the three
screws removed in the previous steps.
Removed
Hanger Tabs
Hanger Tab
Screws
End Plate
Screw
C-Leg
C-Leg Stand
Form No. GRCEM1-1115
CL-High
311 mm
(12-1/4")
T-Leg Stand Mounting
T-Leg stands are available in the following heights:
• Standard wattage units = 254 mm (10")
• High wattage units = 343 mm (13-1/2")
T-Leg Footprint Dimension
Perform the following procedure to install a T-Leg stand on each
end of the unit.
1. Position the unit upside-down on a flat surface.
2. Install sneeze guard(s), if applicable (refer to the OPTIONS
aND aCCESSORIES section for details on installing a
sneeze guard).
3. align the mounting bracket with the end cover on the
underside of the unit, and remove the two screws on the
end cover that match up with the holes on the mounting
bracket.
4. Secure the mounting bracket to the unit with the two end
cover screws.
5. Remove the two hanger tab screws and hanger tabs.
6. align the two mounting holes on the small "T" of the T-Leg
with the two hanger tab holes on the end of the unit. Secure
the leg to the unit with the hanger tab screws.
7. align the single mounting hole on the vertical post of the T-
Leg with the hole on the mounting bracket. Secure from
the inside with the supplied screw.
Removed
Hanger Tabs
Hanger Tab
Screws
T-Leg
T-Leg Stand End Mounting
9
INSTALLATION
406 mm (16")
457 mm (18")
305 mm
(12")
End Cover
Screw
Mounting
Bracket