Global Placement Testing Devices
Conduct placement testing with doors and windows both open and closed to ensure acceptable
placement. To placement test a 1-way wireless device after the initial Enroll/Placement test process:
1. Place the alarm panel into individual placement test mode for the VRP-433 zone (see control
panel installation instructions).
2. Press and hold Programming button for 1 second. "Mode Entered" tone (1 long beep) sounds.
VRP-433 is now in global placement test mode. Each zone enrolled on VRP-433 gives
placement test result when tripped.
• If "Good Zone Placement" tone (1 beep) sounds, device location is satisfactory and unit may be
permanently mounted.
• If "Bad Zone Placement" (3 beeps) tone sounds, reposition device and trip zone again. Continue
until "Good Zone Placement" tone (1 beep) sounds.
3. To exit, press Programming button again for 1 second or place cover back on the VRP-433.
"Mode Exited" (3 beeps) tone sounds.
Step 7: Mounting the VRP-433
Permanently mount the VRP-433 only after completing multiple successful placement tests.
To mount the VRP-433:
1. Ensure AC wire is run through channel on back of VRP-433.
2. Remove front cover and secure unit to wall through mounting holes using all 4 wall plugs and
screws provided.
3. Place cover back on VRP-433.
4. Plug AC adaptor into unswitched AC outlet.
Restoring the VRP-433 to Factory Defaults
To restore factory default settings:
1. Within 1 minute of power up, press and hold Programming button for 10 seconds. Sounder
beeps after first second to indicate VRP-433 is in Installer mode. After 10 seconds, VRP-433
emits double long tone and all LEDs light.
2. Release Programming button and immediately press and hold again for 10 seconds. After 10
seconds, VRP-433 emits a 4-second tone and all three LEDs flash.
NOTE: The second button press must occur within 20 seconds of the first or the VRP-433
will exit Enroll/Placement mode.
3. VRP-433 beeps three times and LEDs return to normal state, indicating Installer mode exit. If
Installer mode exits before reset is complete, due either to time-out or tamper, repeat procedure.
Replacing the Battery
Replace the backup battery when it no longer holds its charge.
To replace the battery:
1. Disconnect VRP-433 from AC.
2. Remove front cover from device.
3. Disconnect battery cable from connector.
4. Loosen screw on battery retention bracket and rotate aside.
5. Lift battery out of holder and insert new one.
6. Reposition retention arm and tighten screw.
7. Attach battery cable to connector on PC board.
8. Snap front cover back into place.
9. Re-connect VRP-433 to AC.
7