• If, according to installer, the empty space between the lower part of the
hood and the wall corner has to be filled, it is then necessary to install
the corner spacer 7.1 at the hood basis using two screws 12c (2,9 x 9,5)
supplied.
• Fasten the two screws Vr placed at the hook areas of the hood.
• Hang the hood body on the specific screws 12b (4,2 x 12,7).
• Fasten definitively the support screws 12b (4,2 x 12,7).
• It is possible to level the hood body by adjusting the screws Vr.
• To definitively fix the hood to the ceiling it is necessary to use two re-
maining screws together with plug and washer. These have to be
placed from inside the hood.
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney us-
ing either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is
left to the installer.
• To install a ø 120 mm air exhaust connection, insert the reducer flange
9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not supplied).
• Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Insert the extension pieces 14.1 laterally on the air outlet connection
piece 15.
Fix the connection piece with the extension pieces onto the support 7.3
using the two screws 12c (2,9 x 9,5) provided.
• Insert the assembled unit inside the upper chimney support 7.4 using
the 4 screws 12c (2,9 x 9,5) provided.
• Connect the hood with the air outlet connection piece using a rigid or a
flexible ø150 tube chosen by the installer. It will be necessary to use
narrow strips (not provided) for this connection.
• Make sure that the charcoal filter has been mounted inside the hood.
EN