INSTALLATION REQUIREMENTS
InstallatIon clearances
When selecting the installation location for the Tungsten
Series Heaters, the following mounting clearances should be
followed.
Care should be taken to ensure that the heater is not installed:
• Where heat/ignition can cause damage to gas cylinders/
lines
• Near other combustible materials
• In open locations subject to rain
• In indoor residential locations
• In areas without sufficient clearances (refer below)
Note: When Installing with No protective cover, the following
installation clearances shall apply:
B
Minimum height to combustible materials
Model
A
300 Series
3ft
500 Series
3ft
Note: Heater should be installed in such a way so as to allow
adequate;
Clearance around air openings to combustion chamber
Clearance from combustible material
Provisions for accessibility and clearance for combustion and
ventilating air supply.
A
C
B
C
3ft
8ft
3ft
8ft
www.bromicheating.com
CONTINUED...
Note: When installing with the Tungsten Smart-Heat
Heat Shield (Part No. 2620165 or 2620166) the following
installation clearances Shall Apply:
Minimum height to combustible materials
Model
A
300 Series
14"
500 Series
14"
B
C
3ft
8ft
3ft
8ft